Henny Penny OE-100 ユーザーズマニュアル

ページ / 22
2-3
Henny Penny
Model OE-100
2-5.
HIGH TEMPERATURE
LIMIT CONTROL
The high temperature limit control is a manual reset control which
senses the temperature of the shortening. If the shortening temperature
exceeds the safe operating limit, this control will open and shut off the
heat to the frypot.
The high limit light will then illuminate and control must manually be
reset.
Disconnect the two wires from the high limit temperature control.
Check for continuity between the two terminals after resetting the
control. If the circuit is open, replace the control following these
procedures. If the circuit is closed, the high limit is not defective.
Reconnect the two electrical wires.
1091
2-4.
THERMAL SENSOR
(Continued)
4. Unplug electrical wires from control panel board that are attached
to thermal sensor.
5. Using a 1/2" wrench, loosen screw nut from pot fitting and pull
thermal sensor bulb straight out from pot fitting.
6. Install new thermal sensor, making sure the thermal sensor ex-
tends through pot wall, up to the outer diameter of the heating
element.
Care must be taken not to extend the thermal sensor
beyond this point or damage of sensor could result. Also,
when installing new thermal sensor, you must use a new
locking ferrule in screw nut. Do not overtighten screw nut.
Snug screw nut up and tighten 1/4 turn past this point.