Henny Penny 291 ユーザーズマニュアル
Model 291
1-4. ERROR CODE TABLE
(Continued)
(Continued)
DISPLAY
CAUSE
PANEL BOARD CORRECTION
“E-41”, “E-46”
Programming
Turn switch to OFF, then back to ON, if display shows any
Failure
of the error codes, try to reinitialize the control; if error code
persists, have the control board replaced
persists, have the control board replaced
“E-47”
Analog converter
Turn switch to OFF, then back to ON, if “E-47” persists,
chip or 12 volt
have the I/O board, or the PC board replaced; if speaker
supply failure
tones are quiet, probably I/O board failure
“E-48”
Input system
Have PC board replaced
error
“E-70 B”
Faulty power
Have power switch checked, along with its wiring; have
switch, or switch
Input/Output board replaced if necessary
wiring; faulty
I/O board
I/O board
“E-92”
24 VAC fuse
Have components, in 24-volt circuit (I.E., hi limit, drain switch)
on I/O board open
checked for shorts
904