Henny Penny 691 ユーザーズマニュアル

ページ / 4
       Model 691
803
       4-3
4-2.  ERROR CODES (Continued)
DISPLAY
CAUSE
PANEL BOARD CORRECTION
“E-41”
Programming
Turn switch to OFF position, then back to ON; if display
failure
shows “E-41”, the control should be re-initialized (see Pro-
gramming section); if the error code persists, replace the
control panel
“E-46”
Eeprom memory
Turn switch to OFF position, then back to ON; if display
write error
shows “E-46”, the control should be re-initialized (see Pro
gramming section); if the error code persists, replace the
control panel
“E-47”
A-to-D failure
Turn switch to OFF position, then back to ON; if display
(Analog converter
shows “E-47”, the control should be re-initialized (see Pro-
chip)
gramming section); if the error code persists, replace the
control panel
“E-48”
Input system
Turn switch to OFF position, then back to ON; if display
error (CPU can’t
shows “E-48”, the control should be re-initialized (see Pro-
read buttons
graming section); if the error code persists, replace the control
digital inputs)
panel
“E-70B”
Faulty power
Have power switch checked, along with its wiring;  have
switch, or switch
Input/Output board replaced if necessary
wiring; faulty
I/O board
“E-92”
24-VAC fuse
Have components, in 24-volt circuit (I.E., hi limit, drain switch)
on I/O board open
checked for shorts