Zanussi 110028 ユーザーズマニュアル

ページ / 5
ZANUSSI
P R O F E S S I O N A L
ACTIVE BLAST CHILLER / FREEZERS
120-180 KG 20 GN 2/1
110026
1 SINGLE SENSOR PROBE
CHILLER+C/FREEZER
1
1
1
1
1
1
INCLUDED ACCESSORIES
Disassembled
l
Power supply - V, phases, Hz
400 V, 3N,
50
400 V, 3N,
50
400 V, 3N,
50
400 V, 3N,
50
400 V, 3N,
50
400 V, 3N,
50
Net weight - kg.
300
180
605
438
605
438
    installed-electric
6.515
6.3
8.335
1.735
8.335
1.735
Power - kW
    at evaporation temperature - °C
-30
-10
-10
-10
-10
Refrigerant power
Refrigeration power - W
4260
20200
20200
20200
20200
Refrigerant type
R404a
R404a
R404a; 
R404a; 
R404a; 
R404a; 
N° defrost in 24 hrs.
3
3/25'
3/30'
3/30'
3/30'
3/30'
Compressor power - HP
4
7,5; 
7,5; 
Max load capacity - trays h 65 mm - n°
20
20
20
20
Trays type
600x400;
GN 2/1
600x400;
GN 2/1
600x400;
GN 2/1
600x400;
GN 2/1
600x400;
GN 2/1
600x400;
GN 2/1
Door hinges
Right Side
Right Side
Right Side
Right Side
Right Side
Right Side
N° and type of door
1
1
1; 
1; 
1; 
2; 
    height
1850
1850
1850
1850
1850
1850
    depth
920
920
946
946
946
946
    width
772
772
752
752
752
752
Internal dimensions - mm
    height
2470
2470
2470
2230
2470
2230
    depth/with open doors
1285, 2099
1285, 2099
1285, 2099
1285, 2099
1285, 2099
1285, 2099
    width
1400
1400
1400
1400
1400
1400
External dimensions - mm
Cooling unit
Built-In
Remote
Built-In
Remote
Built-In
Remote
    UK Guide lines - chilling / freezing
120, 100
120, 100
180, 170
180, 170
180, 170
180, 170
    NF Regulations - chilling / freezing
144, 144
144, 144
144, 144
144, 144
Productivity per cycle - kg.
BCF120A
110091
BCF120RA
110092
BCF180A
110026
BCF180RA
110028
BCF180DA
110027
BCF180RPA
110030
CHARACTERISTICS
MODELS
TECHNICAL DATA
RANGE 
COMPOSITION
Chilling means bringing the temperature of 
cooked food from +90ºC to +3°C in a short 
time lap to minimize bacteria proliferation and 
avoid loss of food consistency and texture. 
The ZANUSSI easyChill Blast 
Chillers/Freezers reduce temperature to 
+3°C at food core in less than 90 minutes 
and down to -18°C in less than four hours. 
After the Blast Chilling a holding cycle starts 
automatically to respectively maintain food at 
+3°C and -18°C. Blast freezed food has a 
solid 6 months/1 year shelf life without loss of 
flavour, nutritional values and weight. The 
opportunity to prepare in a single shot the 
food to be used in different times during the 
week enables a better work scheduling and 
therefore a sensible reduction in labour costs.
FUNCTIONAL AND 
CONSTRUCTION 
FEATURES
 
Soft Chilling (Air temperature 
–2°C). 
 
Hard Chilling (Air temperature 
–20°C). 
 
All the probe-driven cycles feature 
ARTE (Algorithm for Remaining 
Time Estimation): the machine 
displays the actual time needed to 
end the cycle and to make planning 
the activities easier. 
 
Holding at +3°C (automatically 
activated at the end of each cycle). 
 
Turbo cooling: the chiller works 
continuously at the desired 
temperature. Ideal for continuous 
production and for pastry application. 
 
Automatic recognition of the 
insertion of the food probe (cycles 
piloted either by food probe 
temperature or by time)
 
Single sensor core probe as 
standard.