CONNECTING TO GAS SUPPLY 
 
This appliance is designed to be installed with an 
appliance flexible connection only.  Supply piping 
should not be less than R
3
/8.  Connection is made to 
the Rc ½ (½” B.S.P.) female threaded entry pipe 
located just below the hotplate level on the rear left 
hand side of the appliance.  
NOTE: ONLY LIQUID 
SEALANTS TO BE USED WHEN INLET GAS PIPE 
IS FITTED I.E.: DO NOT USE P.T.F.E. SEALANT 
TAPE. 
Carry out a gas tightness test after connecting 
to the gas supply.  The gas bayonet connector must 
be fitted in the shaded area indicated in Fig.4.  Take 
into account that it must be possible to pull the 
appliance forward sufficiently.  Ensure the hose does 
not become trapped when pushing the appliance into 
position. 
IMPORTANT: FLEXIBLE TUBING USED MUST 
COMPLY WITH BS.669 CURRENT EDITION. 
 
 
 
 
 
FITTING THE STABILITY CHAIN 
It is recommended that if the appliance is to be 
installed with a flexible supply pipe, a stability chain 
be fitted and is available from your supplier (see 
Important Safety Requirements).  These instructions 
should be read in conjunction with any leaflet packed 
with the stability chain. 
 
1.  Place the appliance in its intended position and 
level appliance. 
2.  Mark a position 100mm from the top of the rear 
right hand corner. 
3.  Measure down 150mm from this point.  This gives 
the position of the wall anchor point for the 
stability chain. 
4.  The stability chain anchor point on the appliance 
is shown in the diagram Fig. 5. 
 
 
 
 
PRESSURE TESTING 
 
1.  The Triple crown injector is used as a pressure 
test point. 
2.  Connect the pressure gauge to the Triple crown 
injector. 
3.  Check the supply pressure by turning the Triple 
crown burner on and one other hotplate burner 
full on and light the appropriate burner.  The 
pressure should be 20mbar 
4.  Turn off the taps, disconnect the pressure gauge. 
5.  Check operation of each hotplate burner. 
 
 
 
 
 
 
 
Fig.5. 