Electrolux 593804600 ユーザーズマニュアル
![Electrolux](https://files.manualsbrain.com/attachments/3404bb22dccbcfb6fc3ca6ee6cf2547381b94656/common/fit/150/50/424ff1215290c4147facb2112ed5c71f65e2af857b7bc4f69bdf4447be5b/brand_logo.png)
Electrolux Professional S.p.A.
Ovens Platform Customer Support
Technical Training & Service
AOS_Q OVENS – Service manual
(593804600 - ENG)
File: AOS ONE service manual (ENG).01.doc ©Copyright 2007 by Electrolux Professional
P.26/31
Nome Descrizione
hAbo
PWM value at middle power of boiler burners
HabP
Steam condenser engagement in "hot air" mode
hAcA
PWM value at middle power of cavity burners
hAir
Hot air hour counter
hboL
Boiler hour counter
HbYP
Max humidity value to stop the boiler
HCCP HACCP
Mode
hcMb
Combi hour counter
Hdut
Flag to enable heater duty cycle (0=disable; 1=enable)
hHEA
Delay on burner flame ignition after the start of the cavity motor
hStM Steam
hour
counter
Huon
ON phase of the humidifier with combi cycle beetween 50 and 100 degrees
LAMb
Presence of lambda probe (1=yes)
LanG
Language for the menu
Man
Flag to enable manual cookings (0=disable; 1=enable)
nMod
Define if the modification of store program is disable
OCA1
OFFSET of first cavity probe
0lbd
Calibration of the lambda probe (0% of humidity)
PASS
Flag to enable password (0=disable, 1=enable)
PAUT
Flag to enable special programs, i.e. preheating programs and Low temperature
(0=disable; 1=enable)
(0=disable; 1=enable)
PFAC
Flag to enable factory preset recipes (0=disable; 1=enable)
PPM
Flag to enable Peak Power Management (0=disable; 1=enable)
PrEH
Flag to enable cavity preheating during cooking (0=disable; 1=enable)
Sbc
Cooling temperature set for board ventilation
SbYP
Bypass temperature with max. cooking cavity steam temperature (calibration)
SEAL
Altitude above sea level
SinC
Boiler temperature that detect presence of scale
SPHb
Preheating temperature of the boiler
SPHF
Boiler temperature during leavening
Stbo
PWM value at start of boiler burners
StbP
Steam condenser engagement in "boiler" mode
StcA
PWM value at start of cavity burners
StoF
Minimum time for "switch off" of boiler
Ston
Minimum time for "switch on" of boiler
tbon
Timeout for E SL alarm, water level probe alarm
tcdb
Max water temperature for boiler drain
tCMS
Limit of cavity temperature set for working at high temperature
thMA
Define the max. temperature limit for the manual injection of water
tPrn
Print frequency (0=no print)
trMA
Define the max. temperature for water injection during cooling phase
trMn
Define the min. temperature for water injection during cooling phase