Electrolux 593804600 ユーザーズマニュアル

ページ / 31
 
 
 
 
 
Electrolux Professional S.p.A. 
 
Ovens Platform Customer Support 
 
Technical Training & Service 
 
 
 
 
 
AOS_Q OVENS – Service manual 
(593804600 - ENG) 
 
 
 
File: AOS ONE service manual (ENG).01.doc ©Copyright 2007 by Electrolux Professional 
P.26/31 
Nome Descrizione 
hAbo 
PWM value at middle power of boiler burners 
HabP 
Steam condenser engagement in "hot air" mode 
hAcA 
PWM value at middle power of cavity burners 
hAir 
Hot air hour counter 
hboL 
Boiler hour counter 
HbYP 
Max humidity value to stop the boiler 
HCCP HACCP 
Mode 
hcMb 
Combi hour counter 
Hdut 
Flag to enable heater duty cycle (0=disable; 1=enable)  
hHEA 
Delay on burner flame ignition after the start of the cavity motor  
hStM Steam 
hour 
counter 
Huon 
ON phase of the humidifier with combi cycle beetween 50 and 100 degrees 
LAMb 
Presence of lambda probe (1=yes) 
LanG 
Language for the menu 
Man 
Flag to enable manual cookings (0=disable; 1=enable) 
nMod 
Define if the modification of store program is disable 
OCA1 
OFFSET of first cavity probe 
0lbd 
Calibration of the lambda probe (0% of humidity) 
PASS 
Flag to enable password (0=disable, 1=enable) 
PAUT 
Flag to enable special programs, i.e. preheating programs and Low temperature 
(0=disable; 1=enable) 
PFAC 
Flag to enable factory preset recipes (0=disable; 1=enable) 
PPM 
Flag to enable Peak Power Management (0=disable; 1=enable) 
PrEH 
Flag to enable cavity preheating during cooking (0=disable; 1=enable) 
Sbc 
Cooling temperature set for board ventilation 
SbYP 
Bypass temperature with max. cooking cavity steam temperature (calibration) 
SEAL 
Altitude above sea level 
SinC 
Boiler temperature that detect presence of scale 
SPHb 
Preheating temperature of the boiler 
SPHF 
Boiler temperature during leavening 
Stbo 
PWM value at start of boiler burners 
StbP 
Steam condenser engagement in "boiler" mode 
StcA 
PWM value at start of cavity burners 
StoF 
Minimum time for "switch off" of boiler 
Ston 
Minimum time for "switch on" of boiler 
tbon 
Timeout for E SL alarm, water level probe alarm 
tcdb 
Max water temperature for boiler drain 
tCMS 
Limit of cavity temperature set for working at high temperature 
thMA 
Define the max. temperature limit for the manual injection of water 
tPrn 
Print frequency (0=no print) 
trMA 
Define the max. temperature for water injection during cooling phase 
trMn 