 installation 
electrolux e:line ovens 33
32 
electrolux e:line ovens installation
warning
Please follow the points below when installing the appliance
Use an authorised person
•   As stated in the local municipal building codes and
other relevant statutory regulations:
•   Wiring connections must be in accordance with AS/NZS
3000 Wiring Rules and any particular conditions of the
local authority.
•   Refer to data plate for rating information. The data  
plate is positioned behind the bottom of the oven door. 
The circuit diagram is positioned on the top panel of  
the appliance.
•   for appliances with open cooking surfaces, an all pole
disconnect functional switch should be provided near 
the appliance in an accessible position. Refer to AS/
NZS 3000 clause 4.7.1
•   Wiring should be protected against mechanical failure.
Refer to AS/NZS3000 clauses 3.3.2.6, 3.9, 3.10
•   A means of disconnection with a contact separation of
at least 3mm must be supplied in the fixed wiring.
warning
This appliance must be properly earthed.
•  Do not lift the appliance by the door handles.
•   Prepare the cupboard opening to match your appliance
measurements. (See diagrams)
•   Slide appliance into the cupboard, ensuring that the
supply cable (where fitted) does not kink.
•   To prevent tipping, use the screws supplied to secure
your oven into the cupboard by fastening through the  
2 holes to the front panel.
•   Where the appliance is built into a cabinet, the cabinet
must be capable of withstanding 70°C. Installation into
low temperature tolerant cabinetry (e.g. Vinyl coated)
may result in deterioration of the low temperature 
coating by discolouring or bubbling.
•   If the appliance is to be installed adjacent to vinyl
wrapped surfaces, use an installation kit available from 
the vinyl-wrap supplier.
•   Electrolux Home Products cannot accept responsibility
for damage caused by installation into low temperature 
tolerant cabinets.
•   After installation, test and ensure that the appliance
operates correctly before handing it over to the 
customer.
Note:
•   If a powerpoint is fitted it must be accessible with the
appliance installed, as the plug must be accessible
after installation.
warning
To avoid any potential hazard, you must follow our 
instructions when you install your appliance. Failure
to install the appliance correctly could invalidate any 
warranty or liability claims and lead to prosecution.
Installation
Cabinet construction for your appliance
For the best integration within a kitchen, install this appliance  
in a standard 600mm wide cupboard that gives a flush fit  
with the surrounding cupboard fronts. It can also be installed  
using a proud fit.
Flush Fit
16mm
568mm
600mm
20mm
Infill
panel
Cupboard 
door
Oven
100mm
max for 
Pyro oven
Proud Fit
16mm
568mm
600mm
Infill
panel
Cupboard 
door
Oven
100mm
max for 
Pyro oven
Note:
Your appliance must be mounted on a flat surface for the
full width and depth of the product
warning
IMPORTANT: The infill panel MUST not exceed
100mm in length to ensure a 16mm gap is
maintained
Underbench oven
Your underbench oven looks best when the control panel 
is directly under the benchtop. An upper infill panel may
be added if the cooktop placed above the benchtop is too 
deep. Refer to cooktop installation instructions for required 
clearance between cooktop and oven.
Cut-out dimensions
type of fit
A (width) B (height)
C (depth)
flush fit (mm)
600
600
581 min.
Proud fit (mm)
568
590
560 min.
A
C
B
561mm
mounting holes
583mm
596mm
Duo oven Cut-out dimensions
type of fit
A (width) B (height) C (depth)
flush fit (mm)
600
893
581 min.
Proud fit (mm)
568
885
560 min.
Double oven Cut-out dimensions
type of fit
A (width) B (height) C (depth)
flush fit (mm)
600
1086
581 min.
Proud fit (mm)
568
1078
560 min.
min. 650mm
561mm
mounting
holes
A
B
C
mounting holes
596mm
456mm
model
product dimensions  
(h x w x d) mm
electrical connection
min. fuse
rating
max. power
rating
max.
current 
rating
EOEM61CS
595 x 596 x 573
230-240v/50Hz
16A
3.1kW
12.9A
EOEE62CS
595 x 596 x 573
230-240v/50Hz
16A
3.1kW
12.9A
EOEE62CK
595 x 596 x 573
230-240v/50Hz
16A
3.1kW
12.9A
EOEE63CS
595 x 596 x 573
230-240v/50Hz
16A
3.1kW
12.9A
EUEE63CS, EUEE63CK
888 x 596 x 573
230-240v/50Hz
25A
5.3kW
22.1A
EDEE63CS
1081 x 596 x 573
230-240v/50Hz
25A
5.8kW
24.2A
EPEE63CS, EPEE63CK
595 x 596 x 573
230-240v/50Hz
16A
3.1kW
12.9A
min. 650mm
A
561mm
mounting
holes
mounting holes
596mm
456mm
B
C
Hard wiring details
1.  Remove terminal cover plate from rear panel of appliance.
2.  Fit wires through hole in cover plate and make 
connections to terminals.
3.  Engage wires into plastic clip. Secure plastic clip with 
two long silver screws (supplied in separate bag).
4.  Replace cover plate onto rear panel.
Note:
•  Double Oven (Model EDEE63CS)
 This product is to be wired through the bottom access
panel only.
Plastic clips
Plastic clip 
securing points