Graco 3A0237L ユーザーズマニュアル

ページ / 42
Installation
3A0237L
21
Connect Solenoid Kit
A solenoid kit is required for some applicators used with 
Graco Metering Systems. SeIndividual Hoses on 
page 5 to see which applicators require a solenoid kit.
NOTE: To ensure proper operation of valve, install 
the solenoid kit within 15 ft (4.5 m) of the applicator. 
The solenoid reaction time decreases if the solenoid 
kit is farther away from the applicator. Ensure that 
the scuff guard covers the solenoid if mounted 
between the hose and whip hose.
1.
Turn off all power to the system.
2.
Apply anaerobic pipe sealant to pipe threads on 
mufflers (205), tee fitting (202), and swivel fitting 
(215). Connect to valve (201).
3.
Connect elbow fittings (204), and wire harness 
(206) to valve (201).
4.
Connect air hose (C) to swivel fitting (215).
5.
Connect two elbows (207) and tubing (212) to open 
and closed ports on the applicator. See applicator 
manual for port locations.
NOTE: Cut tubing (212) to desired length if neces-
sary.
6.
Install plug (203), or tube fitting (214) and ball valve 
(213) in the other side of the tee fitting (202).
7.
For solenoid kit 24D161: Connect elbow fitting (207) 
and tubing (212) to the purge air port and tube fitting 
(214). See applicator manual for port locations.
Connect Splitter
24D160 and 24D161 use a splitter (211) to allow the 
Graco Metering System to dispense material from the 
system controls.
1.
Connect the splitter (211) to the valve (201) with 
screw (208), washer (209), and nut (210).
2.
Connect the hose communications cable (24) to the 
single splitter (211) connection.
3.
Connect the wire harness (206) and signal cable 
(3b) from the whip hose to the splitter (211).
F
IG
. 14
202
207
212
204
201
205
r_24D161_3a0237b_1b
205
206
C
215
F
IG
. 15
F
IG
. 16
214
203
202
212
207
r_24D161_3a0237B_2b
213
211
208
210
209
24
3b
206
201
r_24D160_3a0237b_1b