Hoshizaki DKM-500BAH ユーザーズマニュアル
5
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
13.3 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
15 A
MAXIMUM FUSE SIZE
15 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*466 (211)
448 (203)
420 (191)
Reference without *marks
80
453 (205)
425 (193)
395 (179)
90
448 (203)
*406 (184)
376 (170)
100
390 (177)
399 (181)
*348 (158)
SHAPE OF ICE
Crescent Cube
ICE PRODUCTION PER CYCLE
7.2 lbs. (3.2 kg) 360 pcs.
APPROXIMATE STORAGE CAPACITY
200 lbs (91 Kg)
APPROXIMATE ICE DISPENSING SPEED
13 lbs/min
(6 kg/min)
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1150 (6.8)
1049 (5.4)
WATER gal./24HR (gal./100 lbs.)
66 (16.3)
110 (23.6)
EXTERIOR DIMENSIONS (WxDxH)
30" x 28" x 77" With 6" Flanged Legs
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
INTERIOR FINISH
Polyethylene 1 pc. Mold
INSULATION
Polyurethane Foam
WEIGHT
Net 385 lbs. ( 175 kg ), Shipping 410 lbs. (186 kg)
CONNECTIONS - ELECTRIC
Cord Connection
- WATER SUPPLY
Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT x 2
CUBE CONTROL SYSTEM
Float Switch
HARVESTING CONTROL SYSTEM
Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL
Timer Controlled. Overflow
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Proximity Switch with Delay
COMPRESSOR
Hermetic, Model RS55C2E-CAA-219
CONDENSER
Air-cooled, Fin and tube type
EVAPORATOR
Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A, 2lbs (907g)
DESIGN PRESSURE
High 467 PSIG, Low 170 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-out ( Internal )
COMPRESSOR PROTECTION
Auto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch
ACCESSORIES -SUPPLIED
N/A
OPERATING CONDITIONS
VOLTAGE RANGE
104 - 127 V
AMBIENT TEMP.
45 -100° F
WATER SUPPLY TEMP.
45 - 90° F
WATER SUPPLY PRESSURE
10 - 113 PSIG
I. Specifications
A. DKM-500BAH
Note: We reserve the right to make changes in specifications and design without prior
notice.