Electrolux EI15IM55GS ユーザーズマニュアル

ページ / 22
15
Operation
Ice Cube Thickness Adjustment
Interval - As Required
Ice thickness adjustments are made using the 
control panel as follows:
       IMPORTANT
Ice thickness adjustment should only be made 
one increment at a time. Allow ice maker 
production to stabilize for 24 hours before 
rechecking ice thickness.
3. 
  Touch and release the LIGHT button key to 
exit the ice thickness adjustment mode.
4. 
  Remove all ice from the storage bin.
5. 
  Ice cubes in any given batch will vary, so 
it is necessary to choose cubes from the 
sample area (Figure 28) for comparison 
when making adjustments. If further 
adjustments are desired, repeat steps 1 
through 4.
1.      To enter the thickness adjustment mode:
 
  a.   Touch and hold the UP ARROW button.
 
  b.   Touch and release the DOWN ARROW      
    button three times, then release the UP  
    ARROW button.
 
  c.   The display will switch to “0,” to confirm  
    the thickness adjustment mode has    
    been selected.
2. 
  The factory setting is “0,” and the total 
range of adjustment is -5 to +5. Use the 
UP ARROW button to raise the setting 
and thicken the ice bridge, or the DOWN 
ARROW button to lower the setting to thin 
the ice bridge.
       IMPORTANT
It is extremely important that Clear Ice models are 
level. If not level, the ice mold will not fill evenly.
SAMPLE AREA
ICE005
Figure 28
ICE
POWER
DOWN
ARROW
LIGHT,
BLACKOUT MODE
& OTHER FUNCTIONS
DISPLAY
UP
ARROW
Figure 27