SERVICE DATA SHEET - 242173700
FREEZER ICE MAKER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a 
 IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel 
only. Untrained persons should not attempt to make repairs due to the possibility 
of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be 
returned to their original position and properly secured.
 
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO 
NOT allow torch to touch insulation; it will char at 200°F and flash 
ignite (burn) at 500°F. Excessive heat will distort the plastic liner.
NOTE
This product comes equipped with an Adaptive Defrost Control (ADC). To activate 
manual defrost, simultaneously press and hold the Fresh Food up (+) and Fresh 
Food down (-) keys for 5 seconds. A “d” in the freezer temperature window 
and “F” in the refrigerator temperature window will display when the heater 
is activated. To deactivate manual defrost, simultaneously press and hold the 
Fresh Food up (+) and Fresh Food down (-) keys for 5 seconds. A “d” and “F” 
will be displayed until the defrost cycle is complete.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° 
CONTROL SETTING (2500++ V4 CONTROLS)
Variable Speed Compressor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
32 to 40%
100%
Freezer Temperature
-6° to 6°F 
-21° to -14°C
-6° to 6°F
-21° to -14°C
Refrigerator Temperature
33° to 46°F 
0.5° to 8°C
33° to 46°F
0.5° to 8°C
Low Side Pressure
(cut-in)  
5 to 12 psig
34 to 83 kPa
N/A
Low Side Pressure
(cut-out)  
-2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure 
85 to 95 psig
586 to 655 kPa
120 to 135 psig
827 to 931 kPa
Wattage 
40 to 55
60 to 70
Amps (running)
0.5 to 1.1
0.7 to 0.9
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat
Heater
Cut-in
Cut-out
Watts
Ohms
23’ SD, 28’ SD, 23’ CD
25°F 
(-4°C)
47°F
(8°C)
500
26
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
(Energy Star, some models)
1100 CW 
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48°F (9°C), Closes at 15°F (-9°C)
Heater Voltage
85 vac
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
Connects to:
1
Green / Yellow
Ground
2
Yellow / Blue
Water Valve
3
Black / Orange
Line
4
Light Blue
Neutral
 IMPORTANT
                                                                                                     
PLEASE RETURN THIS SHEET TO ITS ORIGINAL 
LOCATION.
 
ICE MAKER INFORMATION
Test Cycling:
 Remove cover by inserting screwdriver in notch at  bottom 
and prying cover from housing. Use screwdriver to rotate motor gear counter-
clockwise until holding switch circuit is completed. All components of ice maker 
should function to complete the cycle.  
Water Fill Volume:
 The water fill adjust-
ment screw will change the fill time. One full 
turn is equal to 20cc (.68 oz.). The correct 
fill is 102 to 130cc (3.4 to 4.3 oz.). When a 
water valve is replaced, the fill volume must 
be checked.      
TU
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
POWER
ICE MAKER
I
CE 
M
AKER
ICE 
M
AKER
WATER 
VAL
VE
LINE
THERMAL
CUT-OUT
HOLD
SWITCH
THERMOSTAT
SHUTOFF
SWITCH
WATER FILL
SWITCH
MOLD HEATER
MOLD
MOUNTING
PLATE
165 WATTS
MOTOR
NEUTRAL
BLK / ORG
BLK
BLK
BLK
BLU
C
C
C
NO
NO
NO
NC
NC
NC
LT. BLUE
LT.
 BLUE
BRN
RED
GRN / YEL
GRN / 
YEL
RED
RED
YEL
YEL / BLUE
YEL
P-3
P-1
P-4
P-2
ICE MAKER