Lifebreath CAF-02-MB ユーザーズマニュアル

ページ / 44
14
Options
99-186
Weatherhoods, Two - 6" c/w
1/4" mesh screen
99-130W
Remote Wall Mount Dehumidistat
Control 24 VAC only
99-RSK6
6” back draft damper
99-104
DET - Digital Electronic Timer
Top
Side
29.5"
29.5"
19"
47.5"
6"
6"
14"
12"
4"
19"
22.25"
Supply Air
17.25"
Ventilation
Supply Air
Inlet
Ventilation
Exhaust Air
Outlet
22"
Return Air
Blower Section
 (SERVICE CLEARANCE 1')
 (SERVICE CLEARANCE 3')
Front
Latches
Specifications                  Model CAF-U-L4A-36-P16
Core
Ventilation system has patented aluminum heat recovery core (standard) or an enthalpic energy 
recovery core (optional) for energy-efficient ventilation. Enthalpic cores are recommended for 
regions where the temperature does not drop below 25˚F (-4˚C).
Filters 
Washable air filters in exhaust and supply air streams of ventilation section, 1" pleated in
return plenum side.
Case 
Prepainted galvanized steel for superior corrosion resistance.
Dimensions & Clearances
Note: Ventilation ports and return 
plenum opening available 
off either side of cabinet.
All units conform to CSA 
and UL Standards.
Model
CAF-U-L4A-36-P16
Voltage
120 VAC 60 Hz
Hp
1/2
Amps (total)
8.7
Water
3/4" Copper Soldered
Connections
Connection
Airflow (High)
.25 in wg
1350 CFM
.5 in. wg
1180 CFM
Ventilation
100 - 140 CFM
Airflow
Effectiveness
70%
(Aluminum Core)
Total Efficiency
50%
(Enthalpic Core)
Net Weight
150 lbs.
Shipping Weight
165 lbs.
Warranty
Units carry a lifetime warranty on the heat
recovery (aluminum) core, a five year warranty
on the energy recovery (enthalpic) core and a
five year replacement parts warranty on all
other components.
0212