Tascam CC-222MKII ユーザーズマニュアル

ページ / 40
7 – Reference and specifications—Dimensional drawing
 TASCAM CC-222MKII 
Owner’s Manual
 39
General specifications
Dimensional drawing
Tape maintenance
The heads and tape path should be cleaned and 
demagnetized periodically.
Cleaning the tape path 
Apply head cleaning 
fluid to a cotton bud or soft cloth, and lightly rub the 
heads, capstan and all metal parts in the tape path.
Also clean the pinch roller using rubber cleaning 
fluid.
Both fluids are available in TEAC Tape Cleaning 
Kits HC-2 and RC-2 in the U.S.A. or TZ-261 in other 
areas.
Demagnetizing heads 
Be sure that the power is 
off, then demagnetize the heads using a TEAC E-3 
demagnetizer.
For details of its use, read the instructions supplied 
with the demagnetizer and make sure you understand 
them thoroughly before attempting this operation.
Voltage requirements
USA/Canada 120 VAC, 60 Hz
U.K./Europe 230 VAC, 50 Hz
Australia 240 VAC, 50 Hz
General export 120/230 VAC, 60 Hz
Power consumption
28 W
Applicable electromagnetic environment
E4
Peak inrush current
1.1 A
Dimensions
483 x 138 x 295 (mm)
19 x 5.4 x 11.6 (in)
Weight
7.4 kg (16.3 lbs)
Operating temperature
5°C to 35°C (41°F to 95°F)
Supplied accessories
RC-222 remote control unit
2 x AA batteries
Rack mounting kit
466 m (18.4")
483 mm (19.0")
435mm (17.1")
57.2 mm 
(2.25")
132.5 mm (5.2")
138 mm (5.4")
270 mm (10.6")
15 mm
(0.6")
10 mm
(0.4")
Pinch Roller
Capstan
Erase Head
Record/Play Head