Electrical  connection  and  working  test
• Before  connecting  to  the  mains  supply  ensure  that  the  mains  voltage  corresponds
with  the  voltage  on  the  rating  plate  inside  the  hood.
• Connect  the  cooker  hood  to  the  mains  via  a  double  pole  switch  which  has  3  mm
clearance  between  the  contacts.
• The  appliance  must  be  earthed.
• Once  the  electrical  connection  has  been  completed,  check  that  worktop  illumination,
motor  and  speed  work  properly.
Fitting  the  telescopic  chimney  stack
• Fit the two plastic supports provided to the top part of the hood.
• To fit the upper section item S first expand the chimney slightly to allow it to fit over the
wall brackets (item 2 fig. 1) and then secure the upper section using the 4 screws supplied.
• The lower section item I of the chimney stack should be fitted between the lower bracket
2 and the wall.
• Fix the U-shaped section to the plastic supports, using two of the screws provided in the
bag of accessories (fig. 7).
Part 2
a
OPERATION AND MAINTENANCE INSTRUCTIONS
Fig.  7
S
I