pLan tHe Wiring
Interior Blower Installation
Exterior Blower Installation
prepare tHe DoWnDraFt
Interior Blower Installation
The downdraft is shipped without a blower. Purchase a Model 
VIDV500 Interior  Blower and mount it to the downdraft as follows:
1.  Place the downdraft on its back on a table of flat work surface.
2.  Remove the 
4 nuts and 2 clamp channels.
3.  Remove 
2 screws and the gear motor cover.
4.  Carefully position the blower under the 
bottom flange of the 
downdraft with the 
3¼" x 10" discharge pointed in the desired 
direction.
5.  Connect 
motor plug.
6.  Replace the gear motor cover and 2 sheet metal screws.
7.  Replace the 2 clamp channels and start the 4 nuts, do not 
tighten.
8.  Slide blower left of right to desired position. Use
 cover plate 
(supplied) to close up any open space.
9.  Tighten 4 nuts to secure top of blower. Use 
additional screws 
(supplied) through bottom flange to secure bottom in blower.
NUTS
BLOWER
COVER 
PLATE
CLAMP 
CHANNELS
SCREWS
GEARMOTOR 
COVER
MOTOR 
PLUG
3¼" X 10" 
DISCHARGE
ADDITIONAL 
SCREWS
BOTTOM 
FLANGE
pLeaSe note: External blowers must be hard-wired using locally-
supplied wire and connected to the downdraft plug (included).
1.  The Interior Downdraft Blower system draws 4 AMPS and 
requires a 120 VAC, 60 Hz circuit.
2.  The downdraft has a 2 ft. long power cord with a 3-pronged 
plug. Plan to provide a grounded outlet in a location which will 
allow the unit’s power cord to reach.
iMportant - Location oF eLectricaL oUtLet:
 
If Model RDIPR101RSS is being installed in a 30" wide 
cabinet...
 
or Model RDIPR161RSS is being installed in a 36" wide 
cabinet...
   or Model RDIPR151RSS is being installed in a 45" wide 
cabinet...
 
    
   ...the outlet cannot be located on the back wall 
of cabinet.
 
In these cases, the width of the downdraft covers nearly the 
entire width of the back wall of the cabinet. So you must 
either:
•  mount the electrical box to a side wall or cabinet floor 
 
- at least 12 inches from the back wall.
•  mount  the  electrical  box  to  a  wall  stud  behind  the  
 
cabinet - where it will not be covered by the downdraft 
 
Then provide a clearance hole in the back wall of the  
 
cabinet.
 
 
1.  The Exterior Downdraft Blower system draws 6 AMPS and 
requires a 120 VAC, 60 Hz circuit.
2.  The downdraft has a 2 ft. long power cord with a 3-pronged 
plug. Plan to provide a grounded outlet in a location which will 
allow the unit’s power cord to reach.
iMportant - Location oF eLectricaL oUtLet:
 
If Model RDIPR101RSS is being installed in a 30" wide 
cabinet...
 
or Model RDIPR161RSS is being installed in a 36" wide 
cabinet...
 
or Model RDIPR151RSS is being installed in a 45" wide 
cabinet...
 
    
   ...the outlet cannot be located on the back wall 
of cabinet.
 
In these cases, the width of the downdraft covers nearly the 
entire width of the back wall of the cabinet. So you must 
either:
•  mount the electrical box to a side wall or cabinet floor 
 
- at least 12 inches from the back wall.
•  mount  the  electrical  box  to  a  wall  stud  behind  the  
 
cabinet - where it will not be covered by the downdraft 
 
Then provide a clearance hole in the back wall of the  
 
cabinet.