Viking DCWL ユーザーズマニュアル

ページ / 7
DCWH Designer
Chimney Wall Hood
DCWL Designer
Chimney Wall Hood
w/Ledge
DCWN Designer
Chimney Ledgeless
Wall Hood
P L A N N I N G   A N D   D E S I G N   G U I D E
V I K I N G R A N G E . C O M       •       1 - 8 8 8 - V I K I N G 1
R E L E A S E D 1 2 / 1 / 0 7
© 2 0 0 7   V R C — INFORMATION SUBJECT TO CHANGE 
Proper installation/ducting is extremely
important to ensure maximum
performance. Use a qualified and
trained installer.
VENTILATION
• Check with a qualified and
trained installer or local codes
for makeup air requirements, if
any.
• Max. duct run 
o For 300 – 1,200 CFM—50’
(15.2 m)
o For 1,500 CFM—75’ (22.9 m)
o Duct run length is for general
reference only; always use a
qualified and trained installer.
o Straight runs and gradual
turns are best; for example,
each 90” elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm) of
straight run.
• 7’ round duct for 300 – 600
CFM; 10’ for 900 – 1500 CFM
o Never use flexible duct; it
creates back pressure/air
turbulence and greatly
reduces performance.
GAS
Not applicable
ELECTRICAL
• Hardwire direct with two-wire
with ground
• 120 VAC/60 Hz 
• Max. amp usage (rating
includes rec. ventilator kit
rating)
PLUMBING
Not applicable
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs.
Note: Maximum amp rating for hoods includes recommended ventilator kit rating. All products must be hard wired with two-wire ground. An interior- or
exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
VENTILATION
Built-In Classic Chimney Wall Hood—
Standard, w/Ledge, & Ledgeless
Installation Requirements
Model
Ventilator kits
Duct size
Max. amps   
Interior
Exterior
Interior
Exterior
Interior
Exterior
DCWH3042
DIV300/DIV440
DEV900/DEV1200
7” (17.8 cm)
10” (25.4 cm)
1.7/3.2
6.6/3.9
DCWH3644
DIV300/DIV600*
DEV900/DEV1200*
7” (17.8 cm)
10” (25.4 cm)
1.7/3.9
6.6/3.9
DCWH4244
DIV600
DEV900/DEV1200*
7” (17.8 cm)
10” (25.4 cm)
3.9
6.6/3.
DCWH4844
DIV1200*
DEV1200/DEV1500**
10” (25.4 cm)
10” (25.4 cm)
7.3
4.3/5.1
DCWL3342
DIV300/DIV440
DEV900/DEV1200
7” (17.8 cm)
10” (25.4 cm)
1.7/3.2
6.6/3.9
DCWL3944
DIV300/DIV600*
DEV900/DEV1200*
7” (17.8 cm)
10” (25.4 cm)
1.7/3.9
6.6/3.9
DCWL4544
DIV600
DEV900/DEV1200*
7” (17.8 cm)
10” (25.4 cm)
3.9
6.6/3.9
DCWL5144
DIV1200
DEV1200/DEV1500**
10” (25.4 cm)
10” (25.4 cm)
7.3
4.3/5.1
DCWN3042
DIV300/DIV440
DEV900/DEV1200
7” (17.8 cm)
10” (25.4 cm)
1.7/3.2
6.6/3.9
DCWN3644
DIV300/DIV600*
DEV900/DEV1200*
7” (17.8 cm)
10” (25.4 cm)
1.7/3.9
6.6/3.9
DCWN4244
DIV600
DEV900/DEV1200*
7” (17.8 cm)
10” (25.4 cm)
3.9
6.6/3.9
DCWN4844
DIV1200*
DEV1200/DEV1500**
10” (25.4 cm)
10” (25.4 cm)
7.3
4.3/5.1
Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly
overstated.
UTILITY REQUIREMENTS