For best results, use no more than three 90°  
elbows.  Make sure that there is a minimum 
of 24" of straight duct between elbows if more 
than one is used.  Do not install two elbows 
together.  If you must elbow right away, do it 
as far away from the hood's exhaust opening 
as possible.
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
9.0 feet
10.0 feet
0.0 feet
19.0 feet
FIGURE 5
3.0 feet
5.0 feet
12.0 feet
0.0 feet
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE  4
CALCULATE  THE  DUCTRUN  LENGTH
The ductrun should not exceed 35 equivalent feet 
if ducted with the required minimum of 6" round 
duct.    Calculate  the  length  of  the  ductwork  by 
adding the equivalent feet in 
FIGURE 4 for each 
piece of duct in the system.  An example is given 
PLAN  THE  DUCTWORK
The Magnum  rangehood is designed to offer wide 
flexibility of installations.  The rangehood can be 
ducted vertically or horizontally through a 6" round 
vent.  The unit can also be installed in a recirculating 
configuration.  
FIGURES 1 and 2 show vertical 
and horizontal installations for this unit. 
 FIGURE 
3 shows recirculating installation.
The  Magnum  requires  6"  round  ductwork.    To 
ensure  that  the  blower  performs  to  its  highest 
possible  capacity,  ductwork  should  be  as  short 
and straight as possilbe.
WARNING!    BEFORE  MAKING  ANY  CUTS  OR 
HOLES FOR INSTALLATION, DETERMINE WHICH 
VENTING METHOD WILL BE USED AND CAREFULLY 
CALCULATE ALL MEASUREMENTS.
FIGURE 1
FIGURE 2
ceiling
enclosed soffit
side view
rangehood
cooking surface
upper
cabinet
RECIRCULATING  INSTALLATIONS
For recirculating installations, 
Charcoal Filters are necessary. Remove all 
grease filters and set aside.  Attach one charcoal filter to each end of the 
blower.  Each charcoal filter attaches to the black grid on the side of the 
blower.  Rotate the filter clockwise to install and counterclockwise to remove 
(FIGURE 3C).  Replace all  grease filters.  Some ductwork must be installed to 
exhaust the rangehood back into the kitchen, either at the top of the cabinet  
(FIGURE 3A) or at the face or side of the soffit (FIGURE 3B).  This duct 
work must not terminate into a dead air space.
ceiling
open space
side view
rangehood
cooking surface
upper
cabinet
FIGURE 3A
FIGURE 3B
FIGURE 3C
   WARNING
Because  of  the  weight  and  size  of  the 
rangehood  canopy,  two  or  more  people 
are  needed  to  move  and  safely  install  the 
rangehood canopy.
Failure to properly lift rangehood could result 
in damage to the product or personal injury.
PERSONAL INJURY HAZARD
!