Dacor DHI542 ユーザーズマニュアル

ページ / 16
5
p
lanninG
 
the
 l
ocation
Carefully check the location where the hood is to be
installed. The hood should be placed for convenient
access. Make certain that electrical power can be
provided in the selected location.
Install the range hood and cooking appliance(s) so that
they can be removed if service is required.
Plan the installation so that all minimum dimensions
are met or exceeded (see page 3). Dimensions shown
provide minimum clearances, unless otherwise noted.
Preparing the Mounting Bracket Location
The mounting bracket must be attached directly to the
studs in the ceiling, or to a reinforced mounting block
secured to the studs. See below for mounting bracket
hole dimensions.
Attach the mounting bracket directly above the center
of the cooktop.
Attach the mounting bracket to the mounting surfaces
with #12 screws (not supplied). The screws must be of
sufficient length to penetrate into the wood mounting
surfaces at least 1 1/2” (3.8 cm).
The mounting surface must be level.
Allow clearance in the center of the mounting bracket
for the exhaust duct to pass through the ceiling
(8-inches in diameter).
e
lectrical
 p
ower
 S
upply
Electrical Specifications
It is the owner’s responsibility to ensure that the electrical
connection of this appliance is performed by a qualified
electrician. The electrical installation, including minimum
supply wire size and grounding, must be in accordance with
the National Electric code ANSI/NFPA* (or latest revision)
and local codes and ordinances.
Connect the hood to a 120 Vac, 60 Hz dedicated,
grounded, circuit protected by a 15 Amp circuit breaker or
time delay fuse.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
 WARNING
The electrical service to the range hood should be
installed only by a licensed electrician.
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
DO NOT
use the mounting anchors provided with the
unit. They are part of a standard mounting hardware
package provided with many Dacor hoods, but not
suitable for use with this model.
The range hood is heavy. To prevent personal injury
and property damage caused by the hood coming
loose from the ceiling, mount the hood mounting
bracket only as specified below.
p
reparing
 
for
 i
nsTallaTion
12 9/16”
(31.9 cm)
6 1/8” 
(15.6 cm)
11”