Advantech EKI-2741LX ユーザーズマニュアル
9 Chapter2
2.2 DIP-Switch
The DIP-Switch is used to configure operation mode for LFP (Link Fault Pass-
Through) and operation mode for UTP/Fiber port. The default value of DIP-switch is
OFF.
Through) and operation mode for UTP/Fiber port. The default value of DIP-switch is
OFF.
Table 2.2: EKI-2741series DIP-Switch Definition
S/W No
Status
Description
ON
Enables Port/Power Alarm
1
OFF
Disable Port/Power Alarm
ON Enables
LFP
2
OFF Disables
LFP
Link Fault Pass-Through (DIP-Switch 2): When LFP is enabled, it allows UTP link
failures to be reported to the fiber side and also allows Fiber link failures to be reported
to the UTP side. Therefore, a link loss forwarding feature is provided in both UTP and
Fiber side.
Note
Please don’t change the DIP-switch setting when UTP or fiber port is
transmitting or receiving data. It may cause some data error. Besides, if you
change the DIP-switch setting, please power off the converter and power on
again to make the setting effective.
transmitting or receiving data. It may cause some data error. Besides, if you
change the DIP-switch setting, please power off the converter and power on
again to make the setting effective.