Chapter 3 Printer Adjustments
Chapter 3  Printer Adjustments
Sensor Adjustments
The sensing level of both the transparent (see thru) and reflective sensors 
is adjusted separately and independently. Firstly, the sensor type must 
be selected using the Sensor Method Selection shown below. Then the 
adjustment and calibration of the sensor can be made.
Entering Sensor Adjustment Mode
1.  Turn on the power while pushing the Pause key, Feed key, 
and Stop key simultaneously.
Stop key
MENU key
Pause key
Power Switch
2.  After “Sensor Cal Mode” lights up, release the keys to change 
the printer to sensor adjustment setting mode.
Sensor Cal Mode
See Through
Sensor Selection Method (Transparent  Reflective)
To switch from transparent to reflective sensor, hold down the Feed key 
and then press the Stop key. Each time you press the Stop key, you switch 
to back and forth between the two sensor types.
Sensor Cal Mode
See Through
Hold
Press/Release
If the transparent sensor is selected, “See Through” is displayed and 
the buzzer sounds once. If the reflective sensor is selected, “Reflect” is 
displayed and the buzzer sounds twice.