Seagate 100665905 ユーザーズマニュアル

ページ / 42
12
Momentus XT Product Manual, Rev. D
• Idle and Standby timers
Each time the drive performs an Active function (read, write or seek), the standby timer is reinitialized and 
begins counting down from its specified delay times to zero. If the standby timer reaches zero before any 
drive activity is required, the drive makes a transition to Standby mode. In both Idle and Standby mode, the 
drive accepts all commands and returns to Active mode when disc access is necessary.
3.10
Environmental specifications
This section provides the temperature, humidity, shock, and vibration specifications for Momentus XT drives.
3.10.1
Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. 
Actual drive case temperature should not exceed
 
65°C (149°F) within the operating ambient conditions.
Above 1000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet. 
 
3.10.2
Temperature gradient
Operating
20°C per hour (68°F per hour max), without condensation
Nonoperating
35°C per hour (95°F per hour max), without condensation
3.10.3
Relative humidity
Operating
5% to 95% noncondensing (30% per hour max)
Nonoperating
5% to 95% noncondensing (30% per hour max)
3.10.4
Wet bulb temperature
Operating
37.7°C (99.8°F max)
Nonoperating
40°C (104°F max)
3.10.5
Altitude
Operating
–304.8 m to 3,048 m (–1000 ft to 10,000+ ft)
Nonoperating
–304.8 m to 12,192 m (–1000 ft to 40,000+ ft)
3.10.6
Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive 
mounting screws. Shock may be applied in the X, Y or Z axis.
3.10.6.1
Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum 
operating shock of 350 Gs based on half-sine shock pulses of 2 ms. Shocks should not be repeated more than 
one time per axis.
Operating:
0°C to 60°C (32°F to 140°F)
Nonoperating:
–40°C to 70°C (–40°F to 158°F)