Cheetah 36 Installation Guide, Rev. A
19
2.
Configure termination.
If you are installing the drive in a system that has other SCSI
devices installed, terminate only the end devices on the
SCSI bus.
Figure 4 shows the three most common termination configu-
rations. LW model drives do not have internal terminators or
any other way of adding internal termination on the drive.
You must provide external termination to these drives when
termination is required. This is normally done by adding an
in-line terminator on the cable. See Figure 9 on page 27 for
an illustration showing a system configuration that uses an
inline terminator.  
• Use active (ANSI SCSI-2 Alternative 2) single-
ended terminators when terminating a bus oper-
ating in single-ended mode.
• Use SPI-2-compliant active low voltage differential termina-
tors when terminating a SCSI Ultra2 bus operating in LVD
mode.
• Some controllers prefer to remain terminated even if they
are in the middle of the chain. Also, some controllers treat
the internal and external chains as separate logical buses.
This means you may need to terminate both the first and
last devices on both logical buses to achieve proper termi-
nation. If necessary, refer to your system or controller doc-
umentation to see how this is handled in your particular
system.