Electrolux AOFP201CRR ユーザーズマニュアル
Electrolux air-o-chill
Blast Chiller/Freezers 100kg 20GN1/1
Internet: http://www.electrolux.com/foodservice
HDBB030
2009-10-06
Subject to change without notice
WATER REMOTE UNIT FOR C/FREEZER CW 100KG
880035
TROLLEY TRAY RACK F.16X1/1GN,80MM PITCH
922010
TROLLEY TRAY RACK F. 20X1/1GN,63MM PITCH
922007
RILSAN COATED GRID
881061
PRINTER FOR HACCP BASIC VERSION
881532
PASTRY TROLLEY 16(400X600)80MM-20 1/1 LW
922068
PAIR OF 1/1 GN AISI 304 S/S GRIDS
921101
KIT HACCP EKIS
922166
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW
880183
KIT 3 SINGLE SENSOR PROBES FOR BC/BCF
880269
BANQ.TROLLEY-54PLATES-74MM PITCH-20GN1/1
922016
AIR/WATER REMOTE UNIT F.BC+BCF LW 100KG
880059
AIR REMOTE UNIT CHILL+C/FREEZER CW 100KG
880031
2 SINGLE SENSOR PROBES CHILLER+C/FREEZER
880096
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER
880089
ACCESSORIES
3-SENSOR PROBE FOR CHILLER+C/FREEZER
1
INCLUDED ACCESSORIES
Net weight - kg.
200
installed-electric
0.88
Power - kW
at evaporation temperature - °C
-30
Refrigerant power
Refrigeration power - W
5350
Refrigerant type
R404a
N° defrost in 24 hrs.
6
Max load capacity - trays h 65 mm - n°
20
Trays type
GN 1/1; 600x400
Door hinges
Left
N° and type of door
1
height
1783
depth/with open doors
895, 1422
width
1040
External dimensions - mm
Thermometers
Digital
Thermostat
Electronic
Control type
Electronic
Cooling unit
Remote
UK Guide lines - chilling / freezing
100, 85
NF Regulations - chilling / freezing
72, 72
Productivity per cycle - kg.
Type
Blast freezer - 100 kg
TECHNICAL DATA
AOFP201CRR
727152
CONSTRUCTION
•
Automatic heated door frame.
•
Internal and external finishing in 304
AISI stainless steel and back panel in
stainless steel.
stainless steel.
•
High density polyurethane
insulation, 60 mm tickness, HCFC
free.
free.
•
Environmentally friendly: R404a as
refrigerant fluid.
•
Developed and produced in ISO
9001 and ISO 14001 certified factory.
•
Inner cell with fully rounded corners.
•
Door equipped with removable
magnetic gasket with hygienic design.
•
All motors and fan waterproof
protected IP20.
•
Evaporator with anti rust protection.
•
Ventilator (fan) swinging hinged
panel for access to the evaporator for
cleaning.
cleaning.
•
Hot gas defrosting system.
•
Solenoid valves.
•
1 thermostatic expansion valve.
•
Feet 200 mm high.
•
Stand alone printer as optional, built
in on request.
•
PC connection on request, gate RS
485.
INSTALLATION
•
No water connections required.
•
Waste can be plumbed into drain,
but can also be collected in optional
waste container.
waste container.
Installation diagram:
C - Water drain
I - Electrical connection
Y - Connection for appliance lifting
L - Remote electrical connection
N - Cooling water inlet
O - Cooling water outlet
C - Water drain
I - Electrical connection
Y - Connection for appliance lifting
L - Remote electrical connection
N - Cooling water inlet
O - Cooling water outlet