Electrolux AOFP201CRR ユーザーズマニュアル

ページ / 3
Electrolux air-o-chill
Blast Chiller/Freezers 100kg 20GN1/1
Internet: http://www.electrolux.com/foodservice
HDBB030
2009-10-06
Subject to change without notice
WATER REMOTE UNIT FOR C/FREEZER CW 100KG
880035
TROLLEY TRAY RACK F.16X1/1GN,80MM PITCH
922010
TROLLEY TRAY RACK F. 20X1/1GN,63MM PITCH
922007
RILSAN COATED GRID
881061
PRINTER FOR HACCP BASIC VERSION 
881532
PASTRY TROLLEY 16(400X600)80MM-20 1/1 LW
922068
PAIR OF 1/1 GN AISI 304 S/S GRIDS
921101
KIT HACCP EKIS
922166
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW
880183
KIT 3 SINGLE SENSOR PROBES FOR BC/BCF
880269
BANQ.TROLLEY-54PLATES-74MM PITCH-20GN1/1
922016
AIR/WATER REMOTE UNIT F.BC+BCF LW 100KG
880059
AIR REMOTE UNIT CHILL+C/FREEZER CW 100KG
880031
2 SINGLE SENSOR PROBES CHILLER+C/FREEZER
880096
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER
880089
ACCESSORIES
3-SENSOR PROBE FOR CHILLER+C/FREEZER
1
INCLUDED ACCESSORIES
Net weight - kg.
200
    installed-electric
0.88
Power - kW
    at evaporation temperature - °C
-30
Refrigerant power
Refrigeration power - W
5350
Refrigerant type
R404a
N° defrost in 24 hrs.
6
Max load capacity - trays h 65 mm - n°
20
Trays type
GN 1/1; 600x400
Door hinges
Left
N° and type of door
1
    height
1783
    depth/with open doors
895, 1422
    width
1040
External dimensions - mm
Thermometers
Digital
Thermostat
Electronic
Control type
Electronic
Cooling unit
Remote
    UK Guide lines - chilling / freezing
100, 85
    NF Regulations - chilling / freezing
72, 72
Productivity per cycle - kg.
Type
Blast freezer - 100 kg
TECHNICAL DATA
AOFP201CRR
727152
CONSTRUCTION
• 
Automatic heated door frame. 
• 
Internal and external finishing in 304 
AISI stainless steel and back panel in 
stainless steel. 
• 
High density polyurethane 
insulation, 60 mm tickness, HCFC 
free. 
• 
Environmentally friendly: R404a as 
refrigerant fluid. 
• 
Developed and produced in ISO 
9001 and ISO 14001 certified factory. 
• 
Inner cell with fully rounded corners. 
• 
Door equipped with removable 
magnetic gasket with hygienic design. 
• 
All motors and fan waterproof 
protected IP20. 
• 
Evaporator with anti rust protection.
• 
Ventilator (fan) swinging hinged 
panel for access to the evaporator for 
cleaning. 
• 
Hot gas defrosting system. 
• 
Solenoid valves. 
• 
1 thermostatic expansion valve. 
• 
Feet 200 mm high. 
• 
Stand alone printer as optional, built 
in on request. 
• 
PC connection on request, gate RS 
485. 
 
INSTALLATION
• 
No water connections required. 
• 
Waste can be plumbed into drain, 
but can also be collected in optional 
waste container.
Installation diagram:
  
C - Water drain
I - Electrical connection
Y - Connection for appliance lifting
L - Remote electrical connection
N - Cooling water inlet
O - Cooling water outlet