Replacing the injectors
1. Remove the pan supports.
2. Remove the burner caps and crowns.
3. Using a 7 mm socket spanner 
unscrew and
remove the injectors
,
 then replace them
with the ones required for the new type
of gas
 (see the table “Burner
characteristics”).
4.
Reassemble the parts, following the
same procedure backwards.
5. Replace the Gas Type Label (located near
the gas supply connection) with the one
corresponding to the new type of gas. The
label is supplied in the accessories plastic
bag.
Should the feeding gas pressure be different or
variable compared with the required pressure,
an appropriate pressure regulator must be fitted
on the gas supply pipe, in compliance with the
rules in force.
Conversion to LPG
GAS
BURNER
INJECTOR
NOMINAL
REDUCED
NOMINAL
FEEDING
TYPE
TYPE
REFERENCE
THERMAL
THERMAL
FLOW RATE
PRESSURE
1/100 mm
POWER
POWER
 kW
kW
m3/h
g/h
mbar
Rapid
119
2.9
0.65
0.276
Semirapid
96
1.9
0.45
0.181
-
20
Auxiliary
70
1.0
0.33
0.095
-
Rapid
86
2.7
0.65
-
196
Semirapid
71
1.9
0.45
-
138
28-30/37
Auxiliary
50
1.0
0.33
-
73
NATURAL
GAS
(G 2 0 )
LIQUID
GAS
(Butane/
Propane)
Burner characteristics