Electrolux 30 ユーザーズマニュアル

ページ / 16
4
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Electrical Connection
Connect the flexible armored cable that extends from the
surface unit to the junction box using a suitable strain
relief at the point the armored cable enters the junction
box. Then make the electrical connection as follows.
Electrical ground is required on this appliance.
 This appliance is equipped with a
copper conductor flexible cable. If connection is
made to aluminum house wiring, use only special
connectors which are approved for joining cooper
and aluminum wires in accordance with the National
Electrical Code and local codes and ordinances.
Improper connection of aluminum house wiring to
copper leads can result in a short circuit or fire.
Follow the connector manufacturer recommended
procedure closely.
This appliance is manufactured with a frame connected
green (or bare copper) ground wire.
 DO NOT ground to a gas supply pipe.
DO NOT connect to electrical power supply until
appliance is permanently grounded. Connect the
ground wire before turning on the power.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire:
If your cooktop is to be connected to a 3-wire
grounded junction box (see figure 4):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 4.
 You may not ground the cooktop
through the neutral (white) wire if cooktop is used
in a new branch circuit installation (1996 NEC),
mobile home, recreational vehicle, or where local
codes do not permit grounding through the
neutral (white) wire. When grounding through the
neutral (white) wire is prohibited, you must use a
4-wire power supply cable. See Figure 5. Failure to
heed this warning may result in electrocution or
other serious personal injury.
If cooktop is used in a new branch circuit
installation (1996 NEC), mobile home, recreational
vehicle, or where local codes DO NOT permit
grounding through the neutral (white) wire:
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 5.
Figure 4
3-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Black
Wires
Junction
Box
Cable from appliance
Ground Wire
(Bare or Green Wire)
White Wire
(Neutral)
U.L.-Listed Conduit
Connector (or CSA listed)
Red
Wires
White Wire
(Neutral)
Figure 5
4-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Junction Box
Cable from appliance
White
Wires
Black
Wires
Red
Wires
Ground Wire
Ground Wire
(Bare or Green
Wire)
U.L.-Listed Conduit
Connector (or CSA listed)
WARNING
 If connecting to a 4-wire power
supply cable electrical system, the appliance frame
connected ground wire MUST NOT be connected to
the neutral wire of the 4-wire electrical system.