Maytag W10258096A ユーザーズマニュアル

ページ / 40
10
3. Use a 
¹⁵⁄₁₆" combination wrench and an adjustable wrench to 
attach the flexible connector to the adapters. Check that 
connector is not kinked.   
4. Gas supply pipe must not be more than 10" (25.4 cm) above 
the floor.
Complete connection
1. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. If bubbles appear, a 
leak is indicated. Correct any leak found.
3. Remove cooktop burner caps and grates from parts 
package. Align recess in burner caps with pins in burner 
base. Burner caps should be level when properly positioned. 
If burner caps are not properly positioned, surface burners 
will not light. Place burner grates over burners and caps.
4. Plug into a grounded 3 prong outlet.
Verify Anti-Tip Bracket Location
1. Move range close to cabinet opening.
2. Remove cardboard or hardboard from under the range. Using 
2 or more people, gently move range into its final location.
3. Pull storage drawer out completely.
4. To check that the anti-tip bracket is installed, use a flashlight 
and look underneath the bottom of the range.
Look for the anti-tip bracket securely attached to floor or 
wall.
Slide range back so rear range foot is under anti-tip 
bracket.
Level Range
1. Place oven rack in oven. 
2. Place level on oven rack and check levelness of range, first 
side to side; then front to back.
3. If range is not level, pull range forward until rear leveling leg is 
removed from the anti-tip bracket.
4. Use wrench to adjust leveling legs up or down until range is 
level. Push range back into position.
5. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter
A. Gas pressure regulator
B. Adapter
C. Flexible connector
D. Manual shutoff valve
E. 10" (25.4 cm) max. straight pipe
A. Closed valve
B. Open valve
A
B
C
D
E
F
G
H
B
C
A
D
E
A
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING