Maytag AGR4412ADB/Q/S/W ユーザーズマニュアル

ページ / 63
Component Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, 
unless testing requires power and/or gas. 
 
 
©2004 Maytag Services
 16023522 
15 
 
Illustration Component 
Test 
Procedure 
Results 
 
GND
L or N
Input
 
Spark module 
4 + 0 
Test for voltage at terminals 
L and N...............................................
 
Polarity and ground ............................
 
120 VAC 
 
Not subject to polarity 
 
 
Spark module 
2 + 0 
CGL1100AD* 
Test for voltage at terminals...................
 
Polarity and ground................................
120 VAC 
 
Not subject to polarity 
 
 
Holder orifice 
Verify gas pressure (WCP) ....................
 
Check orifice for debris ..........................
4
"
 Natural 
10
"
 LP/Propane 
Clean as needed. 
 
 
Shut-off Valve 
Verify gas supply is turned on. 
Gas is turned on. 
 
 
Shut-off Valve 
Model CPL1100AD* 
Verify gas supply is turned on. 
Gas is turned on. 
 
 
270
° valve 
Verify gas is supplied. 
Orifice adjusted for Natural or LP. 
 
Adjust set screw for simmer control .......
 
 
 
Refer to LP/Nat. conversion instructions. 
 
 
Spark 270
° switch 
Unplug switch harness at rear of 
range. Test for continuity at wire 
terminals. 
Switch in LITE position .........................
Switch in any other position..................
120 VAC 
 
 
Continuity 
Infinite 
 
 
Spark switch 
Model CGL1100AD* 
Unplug switch harness at rear of 
range. Test for continuity at wire 
terminals. 
Switch in LITE position .........................
Switch in any other position..................
120 VAC 
 
 
Continuity 
Infinite 
 
 
Sealed burner 
Verify gas is supplied .............................
Check for obstructions or 
contamination in burner ports.................
Gas present. 
 
Clean/remove any foreign objects. 
Check ignitor for bending/cracking. 
 
 
Open burner 
Model CPR1100AD*, 
LPR1115AD*, 
CP31200AD*, 
CG31200AD* 
Verify gas is supplied .............................
 
Verify air shutter adjusted properly.........
Gas present. 
 
Air shutter opening:  .400" to .500". 
 
 
Open burner 
Models CPL1100AD*, 
CGL1100AD* 
Verify gas is supplied .............................
 
Verify air shutter adjusted properly.........
Gas present. 
 
Air shutter opening:  .435" to .565". 
 
 
Open burner 
Model CGR1110AD* 
Verify gas is supplied .............................
 
Verify air shutter adjusted properly.........
Gas present. 
 
Air shutter opening:  .420" to .460". 
 
 
Pilot burner 
Models CPL1100AD*, 
CPR1100AD*, 
LPR1115AD*, 
CP31200AD*, 
CG31200AD* 
Verify pilot selector cartridge is set to 
the proper gas........................................
 
LP or Natural