KitchenAid KFGS510E 寸法図

ページ / 2
30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
KFGG500E
KFGS510E
KFGS530E
This range is design-certified by CSA International for use with Natural 
gas or, after proper conversion, for use with LP gas.
•  This range is factory set for use with Natural gas. See “Gas 
Conversions” section. The model/serial/rating plate is located 
on the oven frame behind the top right-hand side of the oven door 
has information on the types of gas that can be used. If the types 
of gas listed do not include the type of gas available, check 
with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial/rating plate for use with a different gas 
without consulting the serving gas supplier. See “Gas Conversions” 
section.
Gas Supply Line
•  Provide a gas supply line if 
3
/
4
" (1.9 cm) rigid pipe to the range 
location. A smaller pipe on longer runs may result in insuffient 
gas supply. With LP gas, piping or tubing size can be 
1
/
2
(1.3 cm) minimum. Usually, LP gas suppliers deteremine the size 
and materials used in the system. 
NOTE: Pipe-joint compounds that 
resist the action of LP gas must be used. Do not use TEFLON tape.
Flexible metal appliance connector:
•  If local codes permit, a new CSA design-certified, 4 to 5 ft 
(122 to 152.4 cm) long, 
1
/
2
" (1.3 cm) or 
3
/
4
" (1.9 cm) I.D. 
(inside diameter), flexible metal appliance connector 
may be used for connecting range to the gas supply line.
•   A 
1
/
2
" (1.3 cm) male pipe thread is needed for connection 
to the female pipe threads of the inlet to the appliance 
pressure regulator.
•  Do not kink or damage the flexible metal tubing when moving 
the range.
•  Must include a shutoff valve: 
The supply line must be equipped with a manual shutoff valve. 
This valve should be located in the same room but external 
to the range opening, such as an adjacent cabinet. It should 
be in a location that allows ease of opening and closing. Do not block 
access to shutoff valve. The valve is for turning on or shutting off gas 
to the range.
A. 27 7/8" (70.8 cm) max. depth with handle
B.  36" (91.4 cm) cooktop height (max.) 
with leveling legs screwed in all the way*
C.  47 1/8" (119.7 cm) overall height (max.) 
with leveling legs screwed in all the way*
D. 29 7/8" (75.9 cm) width
E.  25 7/16 (64.6 cm) depth. Back of range 
to front of cooktop**
F.  Model/serial/rating plate (located on the oven 
frame behind the top right-hand side of the oven door)
  *  Model/serial/rating plates may be rotated up from behind the control 
panel for viewing front the front of the range.
 **  Front door and drawer may extend farther forward, 
depending on styling.
Because Whirlpool Corporation includes a continues commitment to improve our products, 
we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, 
see Installation Instructions packed with product. Specifications subject 
to change without notice.
GAS SUPPLY REQUIREMENTS
A
B
C
A. Gas supply line
B. Shutoff valve “open” position
C. To range
F
A
B
C
D
E
†®
TEFLON is a registered trademark of E.I. Du Point De Nemours and Company.
Ref. W10694025A
02/10/15
Type of Gas:
Natural Gas:
Page 1 of 2
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. 
A time-delay fuse or curcuit breaker is also recommended. It is 
recommended that a separate circuit serving only this range 
be provided.