4.  if ports are clogged, clean with a straight pin. Do not 
enlarge  or  distort  port.  Do  not  leave  anything  stuck 
in  the  ports  when  replacing  black  porcelain  burner 
base.
5.  after cleaning the orifice opening and ports, replace the 
burner cap. make sure cap is set straight on burner and 
that the tabs on cap fit into the grooves of burner base.
6. check the burner for proper lighting after cleaning.
note:  If  a  gas  burner  burns  with  an  uneven  orange 
flame,  reposition  the  burner  cap  so  it  sits  flat  on  the 
burner  housing.  If  burner  lights  slowly,  have  your  gas 
service person check the gas pressure to the appliance.
If  a  top  burner  flame  has  been  adjusted  too  low,  the 
electronic ignitor may start to spark. Readjust flame until 
ignitor stops sparking.
When  cleaning  around  the  surface  burner,  use  care.  If 
cleaning cloth should catch the ignitor, it could damage it, 
preventing ignition. 
If surface burner does not light, check if ignitor is broken, 
soiled or wet. If clogged, clean the small port beneath the 
ignitor using a straight pin. 
Wipe acid or sugar spills as soon as the cooktop has cooled 
as these spills will discolor the porcelain.
See Cleaning Guide – Page 31.
oVen Venting 
- gas toP moDels
the oven Vent
%
Hot air and moisture escape from the oven through a vent 
in the center rear of the cooktop. Do not block the vent. 
Poor baking/roasting and bad combustion can result.
The  oven  bottom  must  be  in  place  for  burner  to  bake 
properly on models 1860 and 1867.
To remove, pull oven bottom forward. Note how tabs on 
the oven bottom sit into the oven pan beneath.
gas suPPly system
gas and electrical supplies
Before  connecting  to  the  supply  systems,  be  sure  that 
the  installation  conforms  with  the  local  codes  or,  in  the 
absence  of  local  codes,  with  the  National  Fuel  Code, 
ANSI Z223.1 latest edition or in Canada, CAN/CGA B149 
installation codes. See page 4 for electrical requirements.
gas Piping to range
The  gas  supply  piping  to  the  range  should  be  3/4”  pipe 
which  is  then  reduced  to  1/2”  at  the  regulator.  With 
“LP”  gas,  the  size  of  the  piping  to  the  range  should  be 
determined by your gas fitter.
When  connecting  pipe  to  the  die  cast  regulator,  use  two 
wrenches. Excess pressure or tightening the pipe too tight 
can cause the regulator to crack, resulting in a gas leak or 
a possible fire or explosion.
Make  sure  that  if  flexible  connectors  are  used  in 
connecting the appliance to the gas supply, they are AGA 
and/or  CGA  approved.  Poorly  designed  connectors  can 
be  a  source  of  gas  leaks.  Even  if  AGA/CGA  approved 
flexible  connectors  are  used,  the  customer  should  be 
cautioned  against  kinking  or  damaging  the  connection 
when  moving  or  cleaning  the  range.  This  could  cause  a 
gas leak.
manual shutoff
Install  a  manual  shutoff  valve  in  the  gas  line,  in  an 
accessible  location,  near  the  unit.  Know  where  the  gas 
valve is so you can shut off the gas to the range quickly. 
Suitable  pipe  thread  sealant  must  be  used  which  is 
approved  for  use  with  “LP”/Natural  gas.  Be  sure  to  use 
this thread sealant on all pipe connections.
Pressure testing
The  appliance,  and  its  individual  shutoff  valve  must  be 
disconnected  from  the  gas  supply  piping  system  during 
any  pressure  testing  of  that  system  at  test  pressures  in 
excess of 1/3 psig (3.5kPa).
The appliance must be isolated from the gas supply piping 
system  by  closing  its  individual  manual  shutoff  valve 
during  any  pressure  testing  of  the  gas  supply  system  at 
test pressures equal to or less than 1/2 psig (3.5kPa).
The gas supply pressure for checking the regulator setting 
shall  be  at  least  one  inch  w.c.  above  manufacturer’s 
specified manifold pressure.
gas leak testing
After  the  final  gas  connection  has  been  made,  all  the 
top  burner  valves  should  be  closed  and  the  gas  supply 
and  manual  shutoff  turned  on.  All  connections  in  the 
gas  supply  line  and  in  the  range  should  be  tested  with 
soap  suds  or  electronic  sniffer  for  leaks.  If  a  leak  is 
present, bubbles will appear. The leak should be stopped 
by  tightening  the  joint,  or  unscrewing  completely  and 
applying  additional  pipe  dope  and  re-tightened.  Any 
factory  connections  which  may  have  been  disturbed 
should be retested.
14