exhaust hood Duct location
Figure 3 shows exact center of duct for both four & six burner 
ranges. Cut drywall opening 10 1/4” x 3 3/8”.
Height from floor to center of duct on all installations should 
be 62 1/4”=D.
Note: Electrical receptacle & gas piping should be located in 
center of opening 6” off floor.
Important: If you have purchased the short leg option, D 
dimension will be 60 1/4”.
installing your exhaust hooD
Your  elmira  range  is  equipped  with  a  350  CFM  exhaust 
fan located in the warming cabinet. This fan can be vented 
directly to the outside or, with the use of the #1442 Charcoal 
Filter (included) can recirculate purified exhaust air into the 
room.
Charcoal filter should be changed every six months.
See page 20 for Filter Cleaning and Replacement.
Ventless installation
Remove  the  charcoal  filter  from  the  broiler  pan  and 
remove  plastic  wrap.  Remove  the  two  screws  holding 
the  mesh  filter  in  place  with  a  #2  phillips  or  red  square 
screw driver. Insert the charcoal filter into mesh filter and 
replace the assembly. See figure 4
Figure 4
To increase efficiency of the charcoal filter system, fan air 
should blow against the 45 degree vent deflector at rear of 
stove.
Vented installation
• Remove vent deflector on rear of stove if venting to the
outside and seal screw holes.
• If  the  exhaust  hood  is  to  be  vented,  the  duct  location
must  be  installed  in  accordance  with  figure  3,  page  7. 
Exhaust air must not be vented into a wall, ceiling, attic 
or a concealed space of a building.
note:  Installation  must  be  in  accordance  with  local 
and  national  building  codes.  Use  only  materials  which 
conform  to  codes  in  effect. 
Disconnect  power  before 
doing  any  electrical  work.  Use  only  metal  ducting,  do 
not use plastic. Assemble securely so that in the event of 
a  grease  fire,  the  fire  will  be  contained  within  the  metal 
ductwork.
Never  vent  exhaust  air  into  a  wall,  attic,  ceiling  or  any 
concealed  space  of  a  building,  as  an  accumulation  of 
grease could pose a fire hazard. Dampers on vented hoods 
must  open  freely  and  no  obstruction  should  block  the 
discharge opening.
Important: If you have purchased the optional in-line 
blower, see installation instructions with blower.
8
44 1/4"
Duct
Nickel Rail
Nickel
Rail
15 3/8"
68 1/4"
64 1/4"
62 1/4"
BACK VIEW
OF RANGE
G
C
D
M
N
28 1/2"
I
30 1/8"
A
29 1/2"
L
37 3/8"
F
36 3/8"
E
68 1/4"
N
64 1/4"
M
30 1/2"
BACK VIEW
OF RANGE
Nickel Rail
29 1/2"
68 1/4"
64 1/4"
62 1/4"
Duct
15 3/8"
H
B
C
D
M
N
Figure 3