B. replacing rangetop orifices:
Tools required to replace orifices.
Small adjustable wrench.
1.  Remove the lift off burner cap.
2.  With  the  small  adjustable  wrench,  unscrew  the  brass 
venturi and remove.
3.  Unscrew  the  natural  gas  orifices  in  each  of  the  top 
burners using the 7 mm nut driver included with orifice 
kit. Replace with “LP” orifices listed below.
 
 
nat. gas 
lP/Propane 
Front left superburner takes 
1.75 mm (#50)  .91 mm (#64)  
Other front burners take 
1.32 mm (#55)  .89 mm (#65) 
All rear burners use 
1.09 mm (#57)  .71 mm (#70)
Note: example. Orifices are stamped metric sizes. (00) is 
the number drill equivalent.
4.  Reinstall the brass 
venturi.
Store nat. gas orifices 
and nut driver so they 
are available for future 
conversions.
When  replacing  the 
black  caps,  make  sure 
that the tabs in the cap 
fit  into  the  grooves  of 
the burner base.
warning 
– fire hazard
• Located  gas  supply  shut  off
valve on the press regulator.
• Shut  off  gas  supply  before
converting to LP gas.
• Make all conversions before
turning gas supply valve back on.
Failure  to  follow  these  instructions  could  result  in  fire, 
explosion or other personal injury.
A. PlAstic cover
B.  GAs Pressure reGulAtor cAP with solid end  
fAcinG out
c.  GAs Pressure reGulAtor cAP with hollow  
end fAcinG out
d.  wAsher
e.  GAs Pressure reGulAtor cAP
conversion of regulator to “lP”  
on models 1860 & 1867 (gas oven)
• Locate the regulator at the rear of range (under back legs).
• Remove the plastic cover from the regulator cap.
• With your fingers, turn the nut counter clockwise.
• Do not remove the spring beneath the cap.
• Turn the cap over so LP faces up and reinstall into
regulator.
• Replace plastic cover over regulator cap.
16