Smeg A2PY-6 ユーザーズマニュアル

ページ / 38
 
 
Instructions for the Installer
 
 
48
 
3.  ADAPTING TO DIFFERENT TYPES OF GAS 
 
 
 
Before carrying out the operations described below, disconnect the 
appliance from the electricity supply.
 
 
The appliance is tested with G20 (2H) natural gas at the pressure of 20 
mbar. If it is to be used with other types of gas, the burner nozzles have 
to be changed and the gas tap adjusted to set the minimum flame. To 
replace the nozzles, proceed as described below. 
 
3.1  Changing the hob nozzles 
1.
 
Remove the pan stands, all the burner caps and the flame diffuser 
rings; 
2.
 
Use a 7 mm socket wrench to unscrew the burner nozzles; 
3.
 
Replace the burner nozzles depending on the type of gas to be used (see 
point “3.2 Burner and nozzle characteristics table"). 
Put the burners back into place correctly. 
 
 
Nozzles for the use of town gas (G110 – 8 mbar) are available from 
authorised service centres.