1.  MOUNTING
1-11
1.4
Radar Processor Unit
Mounting considerations
When selecting a mounting location, keep in mind the following points:
•  Locate the processor unit away from heat sources because of heat that can build 
up inside the cabinet.
•  Locate the equipment away from places subject to water splash and rain.
•  Leave sufficient space at the sides and rear of the unit to facilitate maintenance.
•  A magnetic compass will be affected if the processor unit is placed too close to the 
magnetic compass. Observe the compass safe distances on page ii to prevent de-
viation of a magnetic compass.
Mounting procedure
1. Fix the unit with four M6 bolts, or self-tapping screws.
Floor mounting or bulkhead mounting
Note: If you fix the unit, cable entry upside, never remove the screw M3x10 that joints 
the upper case assy. and lower case assy. of the processor unit.
Processor unit
2-   7 FIXING HOLES
R3.5
7
2-FIXING NOTCH
Unfasten this screw.
M3x10
Upper case assy.
Lower case assy.