Furuno 2839S ユーザーズマニュアル
2. WIRING
2-23
2.7
Sensor Adapters (option)
Maximum eight MC-3000S can be connected to a sensor network (for the redundant
connection: 16). The MC-3000S (serial input/output, IEC61162-2/1, 4ch) can connect
max. 10 sensor adapters using the MC1.5-W cables. The maximum number of MC-
3010A units is five.
connection: 16). The MC-3000S (serial input/output, IEC61162-2/1, 4ch) can connect
max. 10 sensor adapters using the MC1.5-W cables. The maximum number of MC-
3010A units is five.
When fabricating the MC1.5-W cables, use the lot terminal (ferrule type, supplied) to
maintain performance. This fabrication requires the optional crimping tool (type:
CRIMPFOX 10S). For the relations between the connectors and rod terminals, see
page AP-2. Also, the stickers attached on the reverse side of the covers show the de-
tailed connections.
maintain performance. This fabrication requires the optional crimping tool (type:
CRIMPFOX 10S). For the relations between the connectors and rod terminals, see
page AP-2. Also, the stickers attached on the reverse side of the covers show the de-
tailed connections.
Attache the cables to the applicable pins.
Use the ferrule-type terminals (supplied) to connect the cables to the terminals in the
sensor adapters. This connection requires a crimping tool (CRIMPFOX10S, option).
sensor adapters. This connection requires a crimping tool (CRIMPFOX10S, option).
Note 1: Use the MC1.5-W cable between the sensor adapters.
Note 2: The total length of the MC1.5-W cables should be less than 6 m to prevent
malfunction.
malfunction.
Pin No.
Cable color
Signal
1
Red
24V_OUT or 24V_IN
2
Black
24V_GND
3
White
MODBUS-A
4
Blue
MODBUS-B
5
Gray
GND
Rod terminal (ferrule type):
After attaching the rod terminal, use the
optional crimping tool CRIMPFOX 10S
to crimp.
After attaching the rod terminal, use the
optional crimping tool CRIMPFOX 10S
to crimp.
6mm
0.5 to 1 mm
How to attach the rod terminal (ferrule type)
Core
Vinyl sheath