Furuno 2839S ユーザーズマニュアル

ページ / 130
iii
SYSTEM CONFIGURATION
Category of Units
Antenna Unit: Exposed to the weather
All other units: Protected from the weather
* These monitors have been approved by the IMO, MU-190 for CAT 2C and CAT 2HC, MU-231 
for CAT 1C and CAT 1HC.  If a different monitor is to be used on IMO vessels, its effective 
diameter must meet the applicable Category requirements: 
  CAT 1C and CAT 1HC: effective diameter 320 mm or higher
  CAT 2C and CAT 2HC: effective diameter 250 mm or higher
For installation, operation and viewing distance of other monitor, see its manuals.
RPU-013
RADAR
PROCESSOR
UNIT
Sub Display 1
Sub Display 2
Gyro Converter
GC-10
Gyrocompass
A-D Converter
Heading Sensor
LAN
110-115/220-230 VAC
1
ø
, 50/60 Hz
Transformer
RU-1803
440VAC
Brake Unit
BR-001/002
** Control Serial MC-3000S, Analog IN MC-3010A, Digital IN MC-3020D, Digital OUT MC-3030D
EC-3000
PROCESSOR
UNIT
Serial 1, 2 
IEC-61162-2
(Gyrocompass
1)
, AIS)
Serial 3 - 8 
IEC-61162-1
(EPFS
2)
(navigator),
SDME
3)
(Speed Log),
Echo sounder,
Wind, Alarm****,
Navtex, etc.)
Digital Out 1 - 6****
1: System Fail
2: Power Fail
3: Normal Close 1
4: Normal Close 2
5: Normal Open 1
6: Normal Open 2
Dashed lines indicate
optional or local supply
equipment.
Sensor Adapter**
or Switching HUB
HUB-100
Radar Control
Unit RCU-025
OR
Trackball Control Unit
RCU-026
ECDIS Control Unit
RCU-024
OR
Radar Control
Unit RCU-025
OR
Trackball Control Unit
RCU-026
Monitor Unit
MU-190*: FCR-21x9
MU-231*: FCR-28x9
Digital In (ACK IN)
VDR
Intelligent Hub
HUB-3000
100-115/220-230 VAC
1
ø, 
50/60 Hz
JB***
1) Use the gyrocompass having an update rate that is adequate for the ship’s rate of turn.
    Gyrocompass must have update rate better than 40 Hz (HSC) or 20 Hz (other than HSC).
2) Connect the EPFS which is approved in accordance with the requirements of the IMO in  
    resolution MSC.112(73) is used. The GPS speed may not meet IMO requirements unless   
    type approved for compliance with IMO resolution MSC.96(72).
3) Connect the SDME which is approved in accordance with the requirements of IMO in 
    resolution MSC.96(72) is used.
For FCR-2139S-BB, a monitor unit is prepared by user.
*** Junction boxes are required for more than 100 m antenna cables.
**** Contact output for Alarm
      (Load current) 250 mA
      (Polarity) Normally Open: 2 ports, Normally Close: 2 ports
      Serial I/O for alarm is also possible, which complies with IEC 61162-1.
Radiator
SN36AF
Performance
Monitor
ANTENNA UNIT
Chassis
RSB-098/099
RSB-100/101/102
(for HSC)
POWER 
SUPPLY 
UNIT 
PSU-007
#
#
#
RU-5693
RU-6522
RU-5466-1
220 VAC, 3ø, 60 Hz
200 VAC, 3ø, 50 Hz
440 VAC, 3ø, 60 Hz
380 VAC, 3ø, 50 Hz
For HSC spec
220 VAC, 3ø, 50 Hz
220 VAC, 3ø, 60 Hz
440 VAC, 3ø, 60 Hz
110 VAC, 3ø, 
60 Hz
220 VAC, 3ø, 
50 Hz
440 VAC, 3ø, 
50 Hz
#: Not available for HSC spec.
1
ø
, 50/60 Hz