2.  WIRING
2-38
2.7.3
How to set jumper blocks in the sensor adapters
MC-3000S
See the jumper blocks in the MC-CS Board (24P0114) referring to the tables that fol-
low.
MC-CS Board (24P0114)
Rotary switch: Use the rotary switch (S2) to set the Modbus address when setting 
connectors J4/J5 to Modbus. The Modbus address set at J4/J5 in the network is not 
used. When setting J4/J5 to IEC61162-1/2, use the default setting (“0”).
Jumper block: 
Use the jumper block J19 to set the termination resistor on/off for the MODBUS com-
munication on the connector J1. For the first and last sensor adapter in a series, their 
termination resistors should be set to ON. Use the MC-CS Board with the default set-
ting because it becomes the “first” adapter in a series.
Set the jumper blocks J14 through J17 to turn the termination resistors on connectors 
J4 through J7 respectively.
Jumper block J19
Connector J1
1-2
SHORT
Termination resistor: ON (default setting)
2-3
OPEN
1-2
OPEN
Termination resistor: OFF
2-3
SHORT