3.  ARPA OPERATION
3-7
3.8
ARPA Target Data
You can show the data for a tracked ARPA target in the data box at the bottom of the 
screen. To display ARPA target data, the menu item [Display] on the [ARPA] menu 
must be set for [On] and the menu item [Data Box] on the [Display] menu must be set 
for [Target] or [All].
1. Use the CursorPad to put the cursor on an ARPA target.
2. Press the ENTER key to show the data of the target.
ARPA target data
The symbol for the selected ARPA target is enlarged double to identify it from other 
symbols.
To remove the data of a target from a data box, put the cursor on its target symbol and 
press the CANCEL/HL OFF key.
Vector reference
Vector time
Target no.
Bearing, range, course,
speed,CPA, TCPA
+
ARPA target
selected for
data display
(B)01
Data box
Cursor
TRUE 06:00<ARPA> No. 02
A
BRG  78.4ºT
RNG  2.032NM
SOG  0.49KN
CRS  73.0º
TRUE 06:00<ARPA> No. 01
B
BRG  29.3ºT
RNG  0.659NM
SOG  0.10KN
CRS  12.3º
(A)02