Furuno FR-8125 ユーザーズマニュアル

ページ / 120
4.  AIS OPERATION
4-8
4.12
CPA/TCPA Alarm
Set CPA (Closest Point of Approach) alarm range and TCPA (predicted Time to CPA) 
alarm time to alert you to targets that can be on a collision course. When CPA and 
TCPA of any AIS target (including a sleeping target) become less than the preset CPA 
and TCPA alarm settings, the audio alarm sounds. The alarm message "COLLISION" 
appears. The target symbol changes to a dangerous target symbol (red) and its vector 
flashes. You can stop the audio alarm and flashing with any key. The dangerous target 
symbol is displayed until the AIS target is not in the CPA and TCPA alarm setting. The 
AIS continuously monitors CPA and TCPA of all AIS targets.
This feature helps identify the targets that can be on a collision course.
1. Press the MENU key to open the menu.
2. Use S or T to select [Target] and press the ENTER key.
3. Use S or T to select [CPA] and press the ENTER key.
CPA options
4. Use S or T to select [CPA] distance and press the ENTER key.
5. Use S or T to select [TCPA] and press the ENTER key.
TCPA options
6. Use S or T to select [TCPA] and press the ENTER key.
7. Press the MENU key to close the menu.
0.5NM
1NM
2NM
3NM
6NM
5NM
Off
12min
6min
5min
4min
3min
2min
1min
30s