Mitsubishi Electronics FR-E700 ユーザーズマニュアル
5
1.2.4
Parameter clear/all parameter clear
POINT
y
Set "1" in Pr.CL Parameter clear, ALLC all parameter clear to initialize all parameters. (Parameters are not cleared
when "1" is set in Pr. 77 Parameter write selection.)
y
Refer to the extended parameter list of
the Instruction Manual (Applied) for parameters cleared with this
operation.
Operation Display
1.
Screen at power-ON
The monitor display appears.
2.
Press
to choose the PU operation mode.
PU indicator is lit.
3.
Press
to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously appears.)
4.
Turn
until
(
) appears.
Parameter clear
All parameter clear
5.
Press
to read the currently set value.
"
"(initial value) appears.
6.
Turn
to change it to the set value "
".
7.
Press
to set.
Parameter clear
All parameter clear
Flicker ··· Parameter setting complete!!
y
Turn
to read another parameter.
y
Press
to show the setting again.
y
Press
twice to show the next parameter.
Setting
Description
0
Not executed.
1
Sets parameters back to the initial values. (Parameter clear sets back all parameters except
calibration parameters and terminal function selection parameters to the initial values.) Refer to the
parameter list of
calibration parameters and terminal function selection parameters to the initial values.) Refer to the
parameter list of
the Instruction Manual (Applied) for availability of parameter clear and all
parameter clear.
REMARKS
are displayed alternately ... Why?
The inverter is not in the PU operation mode.
PU connector or USB connector is used.
1. Press
. [PU] is lit and the monitor (4-digit LED) displays "1". (When Pr. 79 = "0" (initial value))
2. Carry out operation from step 6 again.
and