Mitsubishi Electronics TM-RFM ユーザーズマニュアル

ページ / 144
5. PARAMETERS 
5 -  11 
 
Classification  No. 
Symbol 
Name and function 
Initial 
value 
Unit Setting 
range 
PS17 LTSTS Minute position detection method function selection 
Used to set the response and the load to motor inertia moment ratio of 
the minute position detection method. 
To make the parameter valid, set parameter No.PS08 (Special function 
selection 3) to "
4" (minute position detection method). (Refer to 
section 4.2.5) 
Low response
High response
Response of the minute position detection 
method
0 0
Setting
Response
Setting
Response
0
8
1
9
2
A
3
B
4
C
5
D
6
E
7
F
Middle response
Middle response
Setting
Load inertia 
moment ratio
Setting
7
F
150 times or more
70 times
0
8
1
9
2
A
3
B
4
C
5
D
6
E
Less than 10 times
80 times
90 times
10 times
100 times
20 times
110 times
30 times
120 times
40 times
130 times
50 times
140 times
60 times
Load inertia 
moment ratio
Selecting the load inertia moment ratio at the 
direct drive motor, which decides the response of 
the minute position detection method
 
0000h   
Refer to the 
name and 
function 
column 
PS18 IDLV Minute position detection method identification signal amplitude 
Used to set the identification signal amplitude for the minute position 
detection method. To make the parameter valid, set parameter 
No.PS08 (Special function selection 3) to "
4". 
Identification signal is "100 " when "0000h" is set. (Refer to section 
4.2.5) 
 
0 to 100 
PS19 
0000h 
PS20 
For manufacturer setting 
Do not change these values by any means. 
0000h 
PS21  
0000h 
PS22  
0000h 
S
pec
ia
l s
et
ting param
et
ers
 
PS23  
0000h 
PS24 
0000h 
PS25 
0000h 
PS26 
0000h 
PS27 
0000h 
PS28 
0000h 
PS29 
0000h 
PS30 
0000h 
PS31 
0000h 
 
PS32 
 
 
0000h