Mitsubishi Electronics TM-RFM ユーザーズマニュアル

ページ / 144
4. OPERATION AND FUNCTIONS 
4 -  15 
 
(3) QD75MH   buffer memory address of special setting parameter (No.PS
 
Description 
Buffer memory address 
No. 
Symbol 
(Note) 
Name 
Initial 
value 
Unit 
Axis 1 
Axis 2 
Axis 3 
Axis 4 
PS01 
**LIT1 
Special function selection 1 
0001h 
 
30268 
30468 
30668 
30868 
PS02 
For manufacturer setting 
0000h 
 
30269 
30469 
30669 
30869 
PS03 
 
 0000h 
 
30270 
30470 
30670 
30870 
PS04 
*LIT2 
Special function selection 2 
0003h 
 
30271 
30471 
30671 
30871 
PS05 
LB1 
Servo control position deviation error detection 
level 
9 0.01rev
30272 
30472 
30672 
30872 
PS06 
LB2 
Servo control speed deviation error detection 
level 
100 r/min 
30273 
30473 
30673 
30873 
PS07 
LB3 
Servo control torque deviation error detection 
level 
100 
 30274 
30474 
30674 
30874 
PS08 
*LIT3 
Special function selection 3 
0010h 
 
30275 
30475 
30675 
30875 
PS09 
LPWM  Magnetic pole detection voltage level 
30 
 30276 
30476 
30676 
30876 
PS10 
For manufacturer setting 
0005h 
30277 
30477 
30677 
30877 
PS11  
0064h 30278 
30478 
30678 
30878 
PS12  
01F4h 30279 
30479 
30679 
30879 
PS13  
0000h 30280 
30480 
30680 
30880 
PS14  
0000h 30281 
30481 
30681 
30881 
PS15  
0000h 30282 
30482 
30682 
30882 
PS16 
 
 0000h 
 
30283 30483 30683 30883 
PS17 
LTSTS  Minute position detection method function 
selection 
0000h  30284 
30484 
30684 
30884 
PS18 
IDLV 
Minute position detection method identification 
signal amplitude 
 30285 
30485 
30685 
30885 
PS19 
For manufacturer setting 
0000h 
30286 
30486 
30686 
30886 
PS20  
0000h 30287 
30487 
30687 
30887 
PS21  
0000h 30288 
30488 
30688 
30888 
PS22  
0000h 30289 
30489 
30689 
30889 
PS23  
0000h 30290 
30490 
30690 
30890 
PS24  
0000h 30291 
30491 
30691 
30891 
PS25  
0000h 30292 
30492 
30692 
30892 
PS26  
0000h 30293 
30493 
30693 
30893 
PS27  
0000h 30294 
30494 
30694 
30894 
PS28  
0000h 30295 
30495 
30695 
30895 
PS29  
0000h 30296 
30496 
30696 
30896 
PS30  
0000h 30297 
30497 
30697 
30897 
PS31  
0000h 30298 
30498 
30698 
30898 
PS32 
 
 0000h 
 
30299 30499 30699 30899 
Note. Parameter whose symbol is preceded by * is made valid with the following conditions. 
* : Set the parameter value, switch power off once after setting, and then switch it on again, or perform the controller reset. 
**: Set the parameter value, switch power off once, and then switch it on again.