Mitsubishi Electronics TM-RFM ユーザーズマニュアル
4. OPERATION AND FUNCTIONS
4 - 15
(3) QD75MH buffer memory address of special setting parameter (No.PS
)
Description
Buffer memory address
No.
Symbol
(Note)
Name
Initial
value
value
Unit
Axis 1
Axis 2
Axis 3
Axis 4
PS01
**LIT1
Special function selection 1
0001h
30268
30468
30668
30868
PS02
For manufacturer setting
0000h
30269
30469
30669
30869
PS03
0000h
30270
30470
30670
30870
PS04
*LIT2
Special function selection 2
0003h
30271
30471
30671
30871
PS05
LB1
Servo control position deviation error detection
level
level
9 0.01rev
30272
30472
30672
30872
PS06
LB2
Servo control speed deviation error detection
level
level
100 r/min
30273
30473
30673
30873
PS07
LB3
Servo control torque deviation error detection
level
level
100
30274
30474
30674
30874
PS08
*LIT3
Special function selection 3
0010h
30275
30475
30675
30875
PS09
LPWM Magnetic pole detection voltage level
30
30276
30476
30676
30876
PS10
For manufacturer setting
0005h
30277
30477
30677
30877
PS11
0064h 30278
30478
30678
30878
PS12
01F4h 30279
30479
30679
30879
PS13
0000h 30280
30480
30680
30880
PS14
0000h 30281
30481
30681
30881
PS15
0000h 30282
30482
30682
30882
PS16
0000h
30283 30483 30683 30883
PS17
LTSTS Minute position detection method function
selection
0000h 30284
30484
30684
30884
PS18
IDLV
Minute position detection method identification
signal amplitude
signal amplitude
0
30285
30485
30685
30885
PS19
For manufacturer setting
0000h
30286
30486
30686
30886
PS20
0000h 30287
30487
30687
30887
PS21
0000h 30288
30488
30688
30888
PS22
0000h 30289
30489
30689
30889
PS23
0000h 30290
30490
30690
30890
PS24
0000h 30291
30491
30691
30891
PS25
0000h 30292
30492
30692
30892
PS26
0000h 30293
30493
30693
30893
PS27
0000h 30294
30494
30694
30894
PS28
0000h 30295
30495
30695
30895
PS29
0000h 30296
30496
30696
30896
PS30
0000h 30297
30497
30697
30897
PS31
0000h 30298
30498
30698
30898
PS32
0000h
30299 30499 30699 30899
Note. Parameter whose symbol is preceded by * is made valid with the following conditions.
* : Set the parameter value, switch power off once after setting, and then switch it on again, or perform the controller reset.
**: Set the parameter value, switch power off once, and then switch it on again.
**: Set the parameter value, switch power off once, and then switch it on again.