C16
(919)
Terminal 1 bias command 
(torque/magnetic flux)
0.1%
0%
0 to 400%
Set the torque/magnetic flux command value on the 
bias side of terminal 1 input. (valid when Pr. 868 
≠ 0, 
5)
C17
(919)
Terminal 1 bias (torque/
magnetic flux)
0.1%
0%
0 to 300%
Set the converted % of the bias side  voltage 
(current) of terminal 1 input. (valid when Pr. 868 
≠ 0, 
5)
C18
(920)
Terminal 1 gain command 
(torque/magnetic flux)
0.1%
150%
0 to 400%
Set the torque/magnetic flux command value on the 
gain side of terminal 1 input. (valid when Pr. 868 
≠ 0, 
5)
C19
(920)
Terminal 1 gain (torque/
magnetic flux)
0.1%
100%
0 to 300%
Set the converted % of the gain side  voltage 
(current) of terminal 1 input. (valid when Pr. 868 
≠ 0, 
5)
C38
(932)
Terminal 4 bias command 
(torque/magnetic flux)
0.1%
0%
0 to 400%
Set the torque/magnetic flux command value on the 
bias side of terminal 4 input. (valid when Pr. 858 
= 1, 
4)
C39
(932)
Terminal 4 bias (torque/
magnetic flux)
0.1%
20%
0 to 300%
Set the converted % of the bias side current (voltage) 
of terminal 4 input. (valid when Pr. 858 = 1, 4)
C40
(933)
Terminal 4 gain command 
(torque/magnetic flux)
0.1%
150%
0 to 400%
Set the torque/magnetic flux command value on the 
bias side of terminal 4 input. (valid when Pr. 858 
= 1, 
4)
C41
(933)
Terminal 4 gain (torque/
magnetic flux)
0.1%
100%
0 to 300%
Set the converted % of the gain side current (voltage) 
of terminal 4 input. (valid when Pr. 858 = 1, 4)
989
Parameter for manufacturer setting. Do not set.
Buz
zer cont
rol 
of
 t
he 
operat
ion 
panel
990
PU buzzer control
1
1
0
Without buzzer
1
With buzzer
 P
U
 co
nt
ras
adjust
ment
991
 PU contrast adjustment
1
58
0 to 63
Contrast adjustment of the LCD of the parameter unit 
(FR-PU04/FR-PU07) can be performed.
0 (Light) 
→ 63 (Dark)
Pa
ra
met
e
r cl
ea
r, 
pa
ra
me
te
r c
o
py
Pr.CL
Parameter clear
1
0
0,  1
Setting "1" returns all parameters except calibration 
parameters to the initial values.
ALLC
All parameter clear
1
0
0, 1
Setting "1" returns all parameters to the initial values.
Er.CL
Faults history clear
1
0
0, 1
Setting "1" will clear eight past faults.
PCPY
Parameter copy
1
0
0
Cancel
1
Read the source parameters to the operation panel.
2
Write the parameters copied to the operation panel to 
the destination inverter.
3
Verify parameters in the inverter and operation panel.
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
Func
tio
n
Parameter
Name
Incre
ments
Initial 
Value
Range
Description
Re
la
te
d
 
p
ara
m
e
te
rs