Mitsubishi Electronics FR-V540-1.5K to 55K ユーザーズマニュアル

ページ / 232
111
Operation selection function 2 (Pr. 65 to Pr. 79)
P
A
RAMETERS
3
3.11.2 Applied motor (Pr. 71, Pr. 450
)
Set the motor used.
When using an other manufacturer’s motor, set "3" or "13" in Pr.71 and perform offline auto tuning. Refer to the 
Instruction Manual (basic) for the motor setting, etc.
<Setting>
• Refer to the following table and set this parameter according to the motor used.
Parameter
Name
Factory Setting
Setting Range
Remarks
71
Applied motor
30
0, 3 to 8, 10, 13 to 18,
 20, 23, 24, 30, 33, 34
450
Second applied motor
9999
0, 10,  30, 9999
9999: Second applied 
motor invalid
Setting
Motor
Control Constants
0
Mitsubishi standard motor (SF-JR)
Inverter internal constants
3
Other manufacturer’s s
tandard motor
Offline auto tuning
4
Offline auto tuning data utilization
5
Star connection direct input
6
Delta connection direct input
7
Star connection direct input + offline auto tuning 
8
Delta connection direct input + offline auto tuning
10
Mitsubishi constant-torque motor
 
 (SF-HRCA)
Inverter internal constants
13
Other manufacturer’s c
onstant-torque 
motor
Offline auto tuning
14
Offline auto tuning data utilization
15
Star connection direct input
16
Delta connection direct input
17
Star connection direct input + offline auto tuning
18
Delta connection direct input + offline auto tuning
20
SF-JR (4P)-1.5kW  or less
(during vector control)
Inverter internal constants
23
Offline auto tuning
24
Offline auto tuning data utilization
30
(factory setting)
SF-V5RU dedicated motor
(including SF-VR type motor)
Inverter internal constants
33
Offline auto tuning
34
Offline auto tuning data utilization
CAUTION
1. Refer to page 120 for offline auto tuning.
2. Refer to page 39 for details of setting conventional Mitsubishi motors and other manufacturer’s 
motors.
CAUTION
Set this parameter correctly according to the motor used.
REMARKS
 For online auto tuning, refer to the Instruction Manual (basic).
speed
torque
position