Mitsubishi Electronics FR-HC2 ユーザーズマニュアル

ページ / 202
121
3
Parameter copy and parameter verification
3.6 Parameter copy and parameter verification
(1) Parameter copy
PCPY Setting
Description
0
Cancel
1
Copy the source parameters to the operation panel.
2
Write the parameters copied to the operation panel into the destination converter.
3
Verify parameters in the converter and operation panel. (Refer to page 122)
REMARKS
When the copy destination is other than the FR-HC2 series converter or when parameter copy is attempted after the parameter
copy reading was stopped, "model error (
)" appears.
Refer to page 188 for the availability of parameter copy.
When the power is turned OFF or an operation panel is disconnected, etc. during parameter copy writing, write again or check
the setting values by the parameter verification.
After a parameter copy, the operation of the converter is in a stop status. Reset the converter after a parameter copy is
completed.
Parameter settings can be copied to multiple converters.
3.
Turn        until               (parameter copy)
     appears.
4.
Press         to read the currently set value.
     "    "(initial value) appears.
5.
Turn        to change it to the setting value 
     "   ".
6.
Press        to copy the source parameters 
     to the operation panel.
7.
Connect the operation panel to the
     copy destination converter.
8.
After performing the steps 2 to 5,
     turn        to change it to "    ".
9.
Press        to write the parameters copied to 
      the operation panel to the destination converter.
10.
When copy is completed, 
        "     " and "             " flicker.
11.
After writing the parameter values to the copy 
        destination converter, always reset the converter, 
        e.g. switch power OFF once, before starting operation.
Display
The parameter 
number previously 
read appears.
Flickers for about 30s
About 30s later
Flicker ··· Parameter copy complete!!
The frequency flickers
 for about 30s
Flicker ··· Parameter copy complete!!
Operation
1.
Connect the operation panel to the 
     copy source converter.
2.
Press         to choose the parameter 
    setting mode.
HC2.book  121 ページ  2012年11月19日 月曜日 午前10時52分