Frequency setting by external terminals
4.6.4
Remote setting function (Pr. 59)
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 190)
....
Specifications differ according to the date assembled.  Refer to page 400 to check the SERIAL number.
* External operation frequency (other than multi-speed) or PU running frequency 
Even if the operation panel is located away from the enclosure, you can use contact signals to perform
continuous variable-speed operation, without using analog signals.
Parameter 
Number
Name
Initial 
Value
Setting 
Range
Description
RH, RM, RL 
Signal Function
Frequency Setting 
Storage Function
Deceleration to the 
Frequency Lower 
Than the Set 
Frequency
59
Remote function 
selection
0
0
Multi-speed setting
1
Remote setting
Used
Disabled
2
Remote setting
Not used
Disabled
3
Remote setting
Not used
(Turning STF/STR 
OFF clears remotely- 
set frequency.)
Disabled
11
Remote setting
Used
Enabled
12
Remote setting
Not used
Enabled
13
Remote setting
Not used
(Turning STF/STR 
OFF clears remotely-
set frequency.)
Enabled
Acceleration
Deceleration
Clear
Inverter
STF
RH
RM
10
2
5
RL
Connection 
diagram for remote setting
Forward 
rotation
SD
Deceleration 
(RM)
Clear (RL)
Acceleration 
(RH)
Forward 
rotation (STF)
ON
ON
Power supply
ON
0Hz
*
ON
ON
ON
ON
ON
ON
When 
Pr. 59 = 1
When 
Pr. 59 = 2, 3
ON
ON
Output frequency 
(Hz)
When 
Pr. 59 = 1, 2
When 
Pr. 59 = 3
Time