WIRING DIAGRAM NOTES
1. Dashed lines are optional.
2. Optional common wire
allows system to power
thermostat.
3. Use “B” or “O” wire - but
not both in heat pump
systems. Generally neither
are required in a
conventional system.
4. If “Y” and “C” wires are
both present, then “C” is a
common wire.
5. If a “B” wire in your
system is a common wire
then connecting it to the B
terminal may cause damage
to your system.
6. The PSPA722 is not
compatible with Heat Pump
Systems.
WARNING: THIS IS A LOW
VOLTAGE THERMOSTAT
(24 volts).  A SERIOUS
RISK OF FIRE EXISTS IF
YOU CONNECT THIS
THERMOSTAT TO A LINE
VOLTAGE APPLICATION
(typically 115 or 230 volts).
IF UNCERTAIN ABOUT THE
VOLTAGE CONSULT A
PROFESSIONAL
ELECTRICIAN.
G
B W2 Y2
O
Y1
W1
RC RH C
TYPICAL 24V AC 5 WIRE HOOKUP
SINGLE STAGE HEAT AND COOL
2 TRANSFORMER
FAN
GAS
VALVE
AC LINE
AC LINE
COMPRESSOR
COOL
COMMON
JUMPER
REMOVED
HEAT
COMMON
COOL
XFMR
HEAT
XFMR
JUMPER
PROVIDED
SYSTEM
COMMON
G
B W2 Y2 O
Y1
W1
RC RH C
TYPICAL 24V MULTI-STAGE
HOOKUP
FAN
AC LINE
HEAT
STAGE 2
STAGE 1
COMPRESSOR
STAGE 2
STAGE 1
XFMR