Mitsubishi Electronics FR-F740P ユーザーズマニュアル

ページ / 410
125
Motor brake and stop operation
4
4.10.3 Selection of a regenerative brake and DC feeding (Pr. 30, Pr. 70)
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 201)
*1
Pr.30 can be set to "1, 11, or 21" for 75K or higher.
*2
Used in combination with GZG, GRZG, or FR-BR.
*3
Used in combination with MT-BR5.
<55K or lower>
<75K or higher>
*1
Used in combination with GZG, GRZG, or FR-BR.
*2
Used in combination with MT-BR5.
When making frequent starts/stops, use the optional brake unit (FR-BU2, BU, FR-BU, MT-BU5) to increase the
regenerative brake duty.
Use a power regeneration common converter (FR-CV) or power regeneration converter (MT-RC) for
continuous operation in regenerative status. 
Use a high power factor converter (FR-HC, MT-HC) to reduce harmonics, improve the power factor, or
continuously use the regenerative mode.
You can select DC feeding mode 1, which operates with DC power supply (terminal P/+, N/-), or DC feeding
mode 2, which normally operates with AC power supply (terminal R/L1, S/L2, T/L3) and with DC power supply
such as battery at power failure occurrence.
Parameter 
Number
Name
Initial 
Value
Setting Range
Description
30
Regenerative function 
selection
0
Regeneration unit
Terminal for power 
supply to the inverter
0
Inverter without regenerative 
function, brake unit (FR-BU2
 
, FR-BU, BU type) 
R/L1, S/L2, T/L3
10
P/+, N/-
(DC feeding mode 1)
20
R/L1, S/L2, T/L3 - P/+, N/-
(DC feeding mode 2)
1
Brake unit (FR-BU2
, MT-
BU5), power regeneration 
converter (MT-RC)
R/L1, S/L2, T/L3
11 
P/+, N/-
(DC feeding mode 1)
21 
R/L1, S/L2, T/L3 - P/+, N/-
(DC feeding mode 2)
2
High power factor converter 
(FR-HC, MT-HC), power 
regeneration common 
converter (FR-CV)
P/+, N/-
70
Special regenerative 
brake duty
0%
0 to 10%
Set the %ED of the brake transistor operation when using 
a brake unit (MT-BU5).
(Setting is available only for the 75K or higher)
Regeneration Unit
Power Supply to the Inverter
Pr. 30 Setting
Inverter without regenerative function, 
brake unit (FR-BU2
, FR-BU, BU)
R/L1, S/L2, T/L3
0
(initial value)
P/+, N/-
10
R/L1, S/L2, T/L3 - P/+, N/-
20
High power factor converter (FR-HC), 
power regeneration common converter 
(FR-CV)
P/+, N/-
2
Regeneration Unit
Power Supply to the Inverter
Pr. 30 Setting
Pr. 70 Setting
Inverter without regenerative function
R/L1, S/L2, T/L3
0
(initial value)
P/+, N/-
10
R/L1, S/L2, T/L3 - P/+, N/-
20
Brake unit (FR-BU2
)
R, S, T
1
0%
(initial value)
P, N
11
R, S, T/P, N
21
Power regeneration converter (MT-RC) R/L1, S/L2, T/L3
1
0%
(initial value)
Brake unit (MT-BU5)
R/L1, S/L2, T/L3
1
10%
P/+, N/-
11
R/L1, S/L2, T/L3 - P/+, N/-
21
High power factor converter (MT-HC)
P/+, N/-
2