Mitsubishi Electronics FR-F740P ユーザーズマニュアル
214
Selection of operation mode and
operation location
4.19.2 Setting the set frequency to operate (example: performing operation at 30Hz)
POINT
Operation panel (FR-DU07) is used to give both of frequency and start commands in PU operation.
Operation example Performing operation at 30Hz.
Operation
Display
1. Screen at power-ON
The monitor display appears.
2. Operation mode setting
Press
to choose the PU operation mode.
PU indicator is lit.
3. Running frequency setting
Turn
to show the frequency "
" (30.00Hz) you
want to set.
The frequency flickers for about 5s.
The frequency flickers for about 5s.
While the value is flickering, press
to set the frequency.
(If you do not press
, the value flickers for about 5s and the
display then returns to "
" (0.00Hz). At this time, return to
"Step 3" and set the frequency again. After the value flickered for
about 3s, the display returns to "
" (monitor display).
Flicker
···
Frequency setting complete!!
After 3s, the monitor display appears.
4. Start
→
acceleration
→ constant speed
Press
or
to
start
running.
The frequency on the display increases in the Pr. 7 Acceleration
time, and "
" (30.00Hz) appears.
/
To change the set frequency, perform the operation in above step 3. (Starting from the previously set frequency.)
5. Deceleration
→ Stop
Press
to
stop.
The frequency on the display decreases in the Pr. 8 Deceleration
time, and the motor stops rotating with "
" (0.00Hz)
displayed.
Operation panel
(FR-DU07)
PU
EXT
NET
Flickers for about 5s
Stop