Initial value change list
4
4
4.27 Initial value change list
Displays and sets the parameters changed from the initial value.
Operation
Display
1.
Screen at power-ON
The monitor display appears.
2.
Operation mode setting
Press
to choose the PU operation mode.
PU indicator is lit.
3.
Press
to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously appears.)
4.
Turn
until
appears.
5.
Pressing
changes to the initial value
change list screen.
6.
Turning
displays the parameter number
changed.
Press
to read the present set value.
Turn
and press
to change the
setting
(refer to step 6 and 7 on page 63)
(refer to step 6 and 7 on page 63)
Flicker
···
Frequency setting complete!!
Turn
to read another parameter.
The display returns to
after all
parameters are displayed.
7.
Pressing
in
status returns to
the parameter setting mode.
Turning
sets other parameters.
Pressing
displays the change list again.
REMARKS
Calibration parameters (C0 (Pr. 900) to C7 (Pr. 905), C42 (Pr. 934) to C45 (Pr. 935)) are not displayed even they are changed from
the initial settings.
Only simple mode parameter is displayed when simple mode is set (Pr. 160 = 9999 (initial value))
Only user group is displayed when user group is set (Pr. 160 = "1").
Pr. 160 is displayed independently of whether the setting value is changed or not.
the initial settings.
Only simple mode parameter is displayed when simple mode is set (Pr. 160 = 9999 (initial value))
Only user group is displayed when user group is set (Pr. 160 = "1").
Pr. 160 is displayed independently of whether the setting value is changed or not.
♦Parameters referred to♦
Pr.160 User group read selection
Refer to page 201
C0(Pr.900) FM terminal calibration
Refer to page 159
C2(Pr.902) to 7(Pr.905) (Frequency setting bias/gain parameter)
Refer to page 193