Mitsubishi Electronics FR-F740P ユーザーズマニュアル

ページ / 410
2/8
BCN-C22005-639
1.2
IPM motor control setting by selecting the parameter setting mode on the 
operation panel (
)
POINT
· The parameters required to drive an IPM motor are automatically changed as a batch.  (Refer to page 3.)
Operation 
example
Initialize the parameter setting for a premium high-efficiency IPM motor (MM-THE4 (1500r/min) 
specification) by selecting the parameter setting mode on the operation panel.
Setting
Description
0
Parameter settings for a general-purpose motor
1
Parameter settings for a high-efficiency IPM motor MM-EF(rotations per minute)
12
Parameter settings for a premium high-efficiency IPM motors MM-EFS and MM-THE4 
(rotations per minute)
22, 32
For manufacturer setting. (Do not set.)
REMARKS
· Performing IPM parameter initialization by selecting the parameter setting mode on the operation panel automatically
changes the Pr. 998 IPM parameter initialization setting.
· The IPM parameter setting is displayed as "1 or 12" in the parameter setting mode even if Pr. 998 IPM parameter
initialization = "101 or 112."
Display
Operation
4. D
isplaying the setting
Press        to read the currently set value. 
"    " (initial value) appears.
2. 
Parameter setting mode
Press        to choose the parameter setting 
mode.
The parameter 
number read 
previously appears.
3. 
Selecting the parameter
1. 
Screen at power-ON
The monitor display appears.
Flicker ... Parameter setting complete!!
6. 
Parameter setting
Press        to set.
 Turn           to read another parameter.
 Press         twice to show the automatic parameter setting (AUTO).
 Press         to show the setting again.
P.RUN indicator is lit.
5. Select
ing the setting
Turn        to change it to the set value "    ".
Turn         until            (IPM parameter
initialization) appears.